基于回復電壓法的變壓器絕緣紙水分及絕緣狀態(tài)研究
發(fā)布時間:2018-05-08 12:44
本文選題:油紙絕緣 + 回復電壓。 參考:《高壓電器》2017年11期
【摘要】:變壓器絕緣紙中水分會加速油紙絕緣的老化,縮短變壓器壽命,因此,準確診斷變壓器絕緣紙老化狀態(tài)以及水分含量對變壓器安全運行具有重要意義。文中通過測試分析不同水分、不同聚合度的絕緣油紙回復電壓曲線,研究發(fā)現當絕緣紙?zhí)幱诘退趾繝顟B(tài)(0.5%≤Mp3%)時,回復電壓參數隨水分含量改變變化較快,當絕緣紙?zhí)幱诟咚趾繝顟B(tài)(3%≤Mp≤5%)時,回復電壓4個參數值基本保持穩(wěn)定;貜碗妷鹤畲笾、初始斜率隨絕緣紙水分含量呈負指數規(guī)律增長,而中心時間常數和回復電壓半衰期呈負指數規(guī)律減小,4個參數隨水分改變的變化幅度均隨絕緣紙聚合度線性變化,通過數據擬合得到回復電壓特征參量與絕緣紙聚合度、水分含量的表達式;貜碗妷喊胨テ谂c絕緣紙水分含量及老化狀態(tài)關系密切,能作為反映固體絕緣紙微水含量和聚合度的有效特征參量。
[Abstract]:Moisture in insulation paper of transformer will accelerate the aging of oil-paper insulation and shorten the life of transformer. Therefore, it is of great significance to accurately diagnose the aging state and moisture content of transformer insulator paper for the safe operation of transformer. Through testing and analyzing the recovery voltage curve of insulating oil paper with different moisture content and different polymerization degree, it is found that when the insulation paper is in the state of low moisture content (0.5% 鈮,