改進(jìn)穿刺針清洗流程的效果評價
本文選題:穿刺針 + 清洗流程 ; 參考:《中國消毒學(xué)雜志》2015年03期
【摘要】:目的提高穿刺針清洗質(zhì)量,避免針刺傷職業(yè)暴露的發(fā)生。方法將臨床使用過的穿刺針分為對照組和試驗(yàn)組,分別采用傳統(tǒng)方法和改良方法進(jìn)行清洗。采用帶光源放大鏡目測法及蛋白殘留測試法對穿刺針清洗效果進(jìn)行評價。結(jié)果對照組放大鏡檢測潔凈度合格率為89%、蛋白殘留測試合格率為95%。試驗(yàn)組放大鏡檢測潔凈度合格率為98%,蛋白殘留測試合格率為100%。結(jié)論改進(jìn)后的清洗流程提高了穿刺針的清洗合格率。
[Abstract]:Objective to improve the puncture needle cleaning quality, avoid needlestick occupation exposure. Methods the clinical use of the puncture needle is divided into control group and experimental group, respectively, using the traditional method and improved method for cleaning. With a magnifier of visual method and protein residue test method to evaluate the puncture needle cleaning effect results in the control group. The magnifying glass to detect the cleanliness of the qualified rate is 89%, protein residue testing qualified rate of test group 95%. magnifier cleanliness testing qualified rate is 98%, protein residue testing qualified rate was 100%. conclusion improved after cleaning process to improve the cleaning of the puncture needle pass rate.
【作者單位】: 四川大學(xué)華西醫(yī)院;
【分類號】:R187
【相似文獻(xiàn)】
相關(guān)期刊論文 前9條
1 田桂登;陳世雄;田雍;;穿刺針清洗方法的改進(jìn)與質(zhì)量管理[J];中華醫(yī)院感染學(xué)雜志;2007年07期
2 高鑫;;穿刺針不同清洗方法質(zhì)量比較[J];中華醫(yī)院感染學(xué)雜志;2009年18期
3 曹登秀;;穿刺針清洗方法的改進(jìn)與質(zhì)量控制[J];中國消毒學(xué)雜志;2013年06期
4 施建輝;魏靜蓉;任輝;李斌;;手術(shù)穿刺針清洗質(zhì)量控制方法的改進(jìn)研究[J];局解手術(shù)學(xué)雜志;2014年03期
5 張紅霞,王明杰,張孝儒;福爾馬林溶液熏蒸消毒穿刺針效果觀察[J];洛陽醫(yī)專學(xué)報(bào);1994年02期
6 田桂登;陳世雄;田雍;;穿刺針清洗方法改進(jìn)后的效果觀察[J];中國消毒學(xué)雜志;2006年06期
7 徐進(jìn);;正確處理穿刺針的體會[J];中國醫(yī)學(xué)創(chuàng)新;2011年01期
8 周繪勤;閆鳳琴;;管腔類器械處理方法探討[J];內(nèi)蒙古中醫(yī)藥;2011年19期
9 ;[J];;年期
相關(guān)會議論文 前2條
1 余曉君;黃浩;向超群;;兩種方法清洗穿刺針的效果分析[A];中華護(hù)理學(xué)會第六屆消毒供應(yīng)中心發(fā)展論壇暨兩岸四地學(xué)術(shù)交流研討會論文匯編(上冊)[C];2010年
2 周雪;魏靜蓉;周婭穎;;穿刺針清洗方法的改進(jìn)與質(zhì)量檢測[A];中華護(hù)理學(xué)會第7屆消毒供應(yīng)中心發(fā)展論壇大會資料[C];2011年
,本文編號:1763199
本文鏈接:http://www.sikaile.net/yixuelunwen/liuxingb/1763199.html