一種容性設備在線監(jiān)測裝置全系統(tǒng)校驗方法研究及校驗系統(tǒng)開發(fā)
發(fā)布時間:2018-10-16 15:55
【摘要】:在總結分析容性設備在線監(jiān)測裝置現(xiàn)有校驗方法的基礎上,提出一種新型的全系統(tǒng)校驗方法,并開發(fā)相應的校驗系統(tǒng),實現(xiàn)容性設備在線監(jiān)測裝置離線條件下泄漏電流和介損值準確性的全量程校驗以及在線條件下實際運行點的校驗。通過量值溯源和現(xiàn)場驗證試驗,證明該校驗系統(tǒng)的介損測量絕對誤差0.1%,電容比率測量相對誤差2%,滿足校驗需求。
[Abstract]:On the basis of summing up and analyzing the existing calibration methods of capacitive equipment on-line monitoring device, a new type of full-system calibration method is proposed, and the corresponding calibration system is developed. The full range calibration of leakage current and dielectric loss accuracy under off-line condition of capacitive equipment on-line monitoring device and the verification of actual operation point under on-line condition are realized. It is proved that the absolute error of dielectric loss measurement and the relative error of capacitance ratio measurement are 0.1 and 2 respectively, which meet the needs of calibration.
【作者單位】: 云南電力試驗研究院(集團)有限公司電力研究院;
【分類號】:TM855
[Abstract]:On the basis of summing up and analyzing the existing calibration methods of capacitive equipment on-line monitoring device, a new type of full-system calibration method is proposed, and the corresponding calibration system is developed. The full range calibration of leakage current and dielectric loss accuracy under off-line condition of capacitive equipment on-line monitoring device and the verification of actual operation point under on-line condition are realized. It is proved that the absolute error of dielectric loss measurement and the relative error of capacitance ratio measurement are 0.1 and 2 respectively, which meet the needs of calibration.
【作者單位】: 云南電力試驗研究院(集團)有限公司電力研究院;
【分類號】:TM855
【參考文獻】
相關期刊論文 前8條
1 李玉忍;高精度電氣設備絕緣介損傳感器的研究[J];傳感技術學報;2000年04期
2 聶鵬,趙學增,張彥,白景峰,趙學濤;高壓電氣設備絕緣在線監(jiān)測系統(tǒng)的研制[J];東北電力學院學報;2000年01期
3 陳天翔,張保會,陳天韜,王江敏,劉軍虎;新型電容型電力設備tanδ在線高精確度測量系統(tǒng)[J];電力系統(tǒng)自動化;2004年15期
4 李耀榮;郝鵬星;余鵬;張劍彪;代紫峰;;絕緣在線監(jiān)測技術在實施中若干問題的探討[J];山西電力;2008年S1期
5 袁紅波 ,王紅斌;高壓設備絕緣在線監(jiān)測影響因素分析[J];華北電力技術;2002年06期
6 張建華;王貽平;郭守賢;;高壓電氣設備絕緣在線監(jiān)測系統(tǒng)現(xiàn)場校驗技術研究[J];華東電力;2009年09期
7 彭亞凱;李振東;羅傳仙;廖源;;一種容性設備絕緣在線監(jiān)測系統(tǒng)現(xiàn)場校驗裝置[J];電工電氣;2011年02期
8 廖源;陸以彪;聞集群;蘇q,