一種互聯(lián)電力系統(tǒng)聯(lián)絡(luò)線功率振蕩特性分析方法及應(yīng)用
本文關(guān)鍵詞:一種互聯(lián)電力系統(tǒng)聯(lián)絡(luò)線功率振蕩特性分析方法及應(yīng)用 出處:《華中科技大學(xué)》2015年碩士論文 論文類型:學(xué)位論文
更多相關(guān)文章: 電力系統(tǒng)低頻振蕩 功率波動(dòng) 阻尼比 廣域測(cè)量 節(jié)點(diǎn)靈敏度
【摘要】:隨著電網(wǎng)規(guī)模的擴(kuò)大,電力系統(tǒng)低頻振蕩問(wèn)題日益突出。廣域測(cè)量系統(tǒng)在電網(wǎng)監(jiān)測(cè)監(jiān)控中的普及,使得低頻振蕩的監(jiān)測(cè)和擾動(dòng)源定位方法也實(shí)現(xiàn)了新的突破。廣域測(cè)量系統(tǒng)歷史數(shù)據(jù)中統(tǒng)計(jì)得到的電網(wǎng)每日發(fā)生有效擾動(dòng)次數(shù)的變化能夠反映系統(tǒng)的穩(wěn)定水平的變化,而系統(tǒng)穩(wěn)定性變化的一個(gè)重要指標(biāo)是系統(tǒng)阻尼比的變化,因此研究并從理論上給出擾動(dòng)次數(shù)和阻尼比的數(shù)學(xué)關(guān)系對(duì)分析和評(píng)估電網(wǎng)的穩(wěn)定性具有重要意義;對(duì)一個(gè)大系統(tǒng),在不同節(jié)點(diǎn)施加擾動(dòng),在聯(lián)絡(luò)線上引起的振蕩幅值和波形不同,即不同節(jié)點(diǎn)施加擾動(dòng)對(duì)聯(lián)絡(luò)線功率振蕩的靈敏度不同。如何利用這種靈敏度信息加速擾動(dòng)源的定位并且做好電網(wǎng)規(guī)劃中負(fù)荷和監(jiān)控節(jié)點(diǎn)的布局,本文也進(jìn)行了相關(guān)研究。本文首先給出了計(jì)及功率擾動(dòng)的小干擾計(jì)算公式,推導(dǎo)出了功率擾動(dòng)下聯(lián)絡(luò)線振蕩波動(dòng)時(shí)域表達(dá)式,并研究了其幅值波動(dòng)值與阻尼比的關(guān)系;基于此理論分析方法,提出了兩種應(yīng)用方式,即基于有效擾動(dòng)次數(shù)的系統(tǒng)阻尼比評(píng)估方法和基于節(jié)點(diǎn)靈敏度的擾動(dòng)源預(yù)判方法,并分別在10機(jī)39節(jié)點(diǎn)系統(tǒng)上和湖北某區(qū)域電網(wǎng)上驗(yàn)證了這些方法的有效性。該理論分析方法可以較為精確得分析擾動(dòng)施加以后經(jīng)過(guò)網(wǎng)絡(luò)方程和系統(tǒng)動(dòng)態(tài)方程的分配過(guò)程,從而替代對(duì)實(shí)際系統(tǒng)的時(shí)域仿真,快速得分析電力系統(tǒng)聯(lián)絡(luò)線的振蕩規(guī)律。其兩種應(yīng)用方式可以通過(guò)觀察近期WAMS記錄到的有效擾動(dòng)次數(shù)的變化來(lái)評(píng)估系統(tǒng)阻尼水平,有效預(yù)警電力系統(tǒng)中的低頻振蕩事故的發(fā)生;并可以通過(guò)對(duì)系統(tǒng)不同節(jié)點(diǎn)靈敏度的分析和排序,在電力系統(tǒng)發(fā)生功率振蕩時(shí),優(yōu)先從節(jié)點(diǎn)靈敏度高的節(jié)點(diǎn)判定其是否為擾動(dòng)源,實(shí)現(xiàn)擾動(dòng)源定位的預(yù)判,以及在電網(wǎng)的規(guī)劃運(yùn)行中合理安排負(fù)荷布局,從而做好關(guān)鍵脆弱節(jié)點(diǎn)的監(jiān)控與防范。
[Abstract]:With the expansion of power network scale, the problem of low frequency oscillation in power system is becoming more and more prominent. Wide area measurement system is widely used in power network monitoring and monitoring. The monitoring of low frequency oscillation and the method of locating the disturbance source have also achieved a new breakthrough. The change of the daily effective disturbance times of the power network obtained from the historical data of the wide area measurement system can reflect the change of the stability level of the system. Turn. One important index of system stability change is the change of system damping ratio, so it is very important to study and give the mathematical relation between the number of disturbances and damping ratio in theory for analyzing and evaluating the stability of power system. For a large system, the amplitude and waveform of oscillation caused by disturbance at different nodes on the tie line are different. That is, the sensitivity of different nodes to tie-line power oscillation is different. How to use this sensitivity information to accelerate the location of disturbance sources and to do a good job in power network planning load and monitoring node layout. In this paper, the formula of small disturbance is given, and the time-domain expression of tie-line oscillation is derived. The relationship between amplitude fluctuation and damping ratio is studied. Based on this theoretical analysis method, two kinds of application methods are proposed, that is, the damping ratio evaluation method based on the effective disturbance number and the disturbance source prediction method based on node sensitivity. The effectiveness of these methods is verified on a 10-machine 39-bus system and a regional power grid in Hubei Province, respectively. The theoretical analysis method can accurately analyze the network equation and the dynamic equation of the system after the disturbance is applied. The distribution process. In order to replace the time domain simulation of the actual system. The oscillation law of tie-line in power system is analyzed quickly. The damping level of the system can be evaluated by observing the change of effective disturbance times recorded by WAMS in the near future. Effective early warning of low-frequency oscillation accidents in power system; Through the analysis and ranking of the sensitivity of different nodes in the power system, when power oscillation occurs, priority is given to the node with high node sensitivity to determine whether the node is a disturbance source, so that the location of the disturbance source can be pre-determined. In order to monitor and prevent the key vulnerable nodes, the load layout is arranged reasonably in the planning and operation of power network.
【學(xué)位授予單位】:華中科技大學(xué)
【學(xué)位級(jí)別】:碩士
【學(xué)位授予年份】:2015
【分類號(hào)】:TM712
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 蘇寅生;曾勇剛;丁軍策;李凌;鄧秋荃;;廣西電網(wǎng)平班電廠“2·26功率振蕩”分析[J];南方電網(wǎng)技術(shù);2007年02期
2 趙書(shū)強(qiáng);范偉;;由風(fēng)力發(fā)電引起的電力系統(tǒng)強(qiáng)迫功率振蕩[J];華東電力;2009年01期
3 董超;云雷;劉滌塵;廖清芬;占才亮;汪如松;王強(qiáng);;原動(dòng)機(jī)周期性擾動(dòng)引發(fā)強(qiáng)迫功率振蕩特性研究[J];電網(wǎng)與清潔能源;2012年04期
4 王哲偉;云雷;盛超;陳曉科;楊汾艷;;電力系統(tǒng)強(qiáng)迫功率振蕩及其影響因素研究[J];陜西電力;2012年09期
5 楊小明;劉滌塵;廖清芬;單增禮;羅恒;張紅麗;;動(dòng)態(tài)近似熵在強(qiáng)迫功率振蕩在線檢測(cè)中的應(yīng)用[J];電網(wǎng)技術(shù);2012年11期
6 蘇寅生;;南方電網(wǎng)近年來(lái)的功率振蕩事件分析[J];南方電網(wǎng)技術(shù);2013年01期
7 李瑩;賈文雙;李文鋒;劉增煌;陶向宇;王官宏;;基于起振段波形在線判別電力系統(tǒng)功率振蕩性質(zhì)[J];中國(guó)電機(jī)工程學(xué)報(bào);2013年25期
8 黃涌;云雷;唐飛;劉滌塵;孫文濤;;電力系統(tǒng)強(qiáng)迫功率振蕩過(guò)程中的功-能轉(zhuǎn)換[J];電力自動(dòng)化設(shè)備;2013年08期
9 F.Ilar ,史卓吾;電網(wǎng)功率振蕩檢測(cè)裝置的改進(jìn)[J];江蘇電力;1985年02期
10 馮賡tD;;檢測(cè)電力網(wǎng)功率振蕩的新方法[J];華北電力技術(shù);1985年11期
相關(guān)會(huì)議論文 前4條
1 劉闖;王建元;李盛楠;邵春雨;;區(qū)域間功率振蕩的相關(guān)性分析[A];中國(guó)高等學(xué)校電力系統(tǒng)及其自動(dòng)化專業(yè)第二十四屆學(xué)術(shù)年會(huì)論文集(上冊(cè))[C];2008年
2 李承秀;王永彬;;Ku波段GaAs功率振蕩模塊[A];1993年全國(guó)微波會(huì)議論文集(下冊(cè))[C];1993年
3 王飛;張文成;;發(fā)耳電廠600MW機(jī)組運(yùn)行中有功功率波動(dòng)分析[A];發(fā)耳電廠4×600MW機(jī)組工程施工論文總結(jié)匯編[C];2010年
4 王飛;張文成;;發(fā)耳電廠600MW機(jī)組運(yùn)行中有功功率波動(dòng)分析[A];貴州省電機(jī)工程學(xué)會(huì)2010年優(yōu)秀論文集[C];2010年
相關(guān)重要報(bào)紙文章 前2條
1 紀(jì)永新;莫讓振蕩再“忽悠”[N];中國(guó)電力報(bào);2006年
2 通訊員 曾逸農(nóng);機(jī)組發(fā)生功率振蕩 四川電網(wǎng)有驚無(wú)險(xiǎn)[N];中國(guó)電力報(bào);2006年
相關(guān)博士學(xué)位論文 前1條
1 韓志勇;電力系統(tǒng)機(jī)網(wǎng)動(dòng)態(tài)安全穩(wěn)定的研究[D];華北電力大學(xué)(北京);2009年
相關(guān)碩士學(xué)位論文 前10條
1 李文旦;風(fēng)電對(duì)系統(tǒng)功率振蕩的影響及阻尼控制研究[D];山東大學(xué);2015年
2 張o坻,
本文編號(hào):1392179
本文鏈接:http://www.sikaile.net/kejilunwen/dianlilw/1392179.html