氟塑料換熱器傳熱特性實驗研究與模型優(yōu)化
發(fā)布時間:2018-01-22 06:54
本文關鍵詞: 氟塑料 換熱器 傳熱模型優(yōu)化 傳熱性能 實驗研究 出處:《中國電機工程學報》2017年08期 論文類型:期刊論文
【摘要】:氟塑料換熱器優(yōu)良的耐腐蝕特性,為電廠低溫煙氣余熱回收提供了新的解決途徑。針對氟塑料換熱器開展實驗研究,氟塑料換熱管束表面光滑對層流邊界層的附加擾動較弱,管外對流傳熱系數(shù)較金屬換熱材料偏低。茹卡烏斯卡斯經(jīng)典關聯(lián)式直接應用于塑料換熱器存在約40%偏差。結合風洞實驗數(shù)據(jù),得到換熱器在不同風速下的總傳熱系數(shù)、管外對流傳熱系數(shù)、空氣阻力特性和各環(huán)節(jié)熱阻分布特性。
[Abstract]:The excellent corrosion resistance of fluoroplastic heat exchanger provides a new solution for waste heat recovery of low temperature flue gas in power plant. The additional disturbance of laminar boundary layer is weak when the surface of fluoroplastic tube bundle is smooth. The convection heat transfer coefficient outside the tube is lower than that of the metal heat transfer material. There is about 40% deviation in the application of the Rucauskas classical correlation formula to the plastic heat exchanger. The total heat transfer coefficient, the convection heat transfer coefficient outside the tube, the air resistance characteristics and the thermal resistance distribution characteristics of the heat exchanger at different wind speeds are obtained.
【作者單位】: 華北電力大學;大金氟化工(中國)有限公司;
【基金】:國家自然科學基金項目(51436006) 中央高;究蒲袠I(yè)務費專項基金(2015ZZD10)~~
【分類號】:TM621
【正文快照】: 0引言燃煤電站鍋爐每年消耗約15億噸標煤,約占全國煤炭消耗總量的50%[1]。為防止鍋爐尾部部件發(fā)生低溫腐蝕,鍋爐排煙溫度一般設計為120~150℃,排煙熱損失占到鍋爐全部熱損失的一半以上,蘊藏著巨大的余熱資源[2]。在實際運行中,由于工況改變、煤種變動、受熱面灰污等原因,部分,