配電網(wǎng)電壓暫降源定位研究
本文關鍵詞:配電網(wǎng)電壓暫降源定位研究 出處:《中國礦業(yè)大學》2016年碩士論文 論文類型:學位論文
更多相關文章: 電壓暫降 源定位 擾動功率 監(jiān)測裝置
【摘要】:現(xiàn)代電力電子技術高速發(fā)展,敏感電力負荷大量應用,而敏感電力負荷對電能質量的要求相較傳統(tǒng)負荷更高,由此造成的用戶對電能質量問題的投訴愈加頻繁,其中80%的投訴事件涉及電壓暫降。電壓暫降早已成為最嚴重的動態(tài)電能質量問題。電壓暫降源定位,就是確定暫降源位于監(jiān)測裝置的哪一側。準確的電壓暫降源定位能夠有效界定配電網(wǎng)中引起電壓暫降的責任方,為供、用電雙方提供解決矛盾的理論依據(jù),同時,暫降源的定位能夠有效評估配電網(wǎng)的薄弱環(huán)節(jié),為電網(wǎng)改造提供指導意見。首先,本文以盱眙縣梁營變電所供電區(qū)域配網(wǎng)為例,研究20k V配電網(wǎng)發(fā)生各種短路故障等擾動時,電壓暫降的傳播域和影響強度,為有效減弱電壓暫降在配電網(wǎng)的危害提供建議。其次,在詳細介紹現(xiàn)有暫降源定位方法的基礎上,本文對已有5種定位方法建模仿真分析,指出包括擾動能量和擾動功率法(Disturbance Energy and Power,DEP)、電流實部極性法(Real Current Component,RCC)、系統(tǒng)軌跡斜率法(Slope of System Trajectory,SST)、距離阻抗繼電器法(Distance Relay,DR)和等效阻抗實部極性法(Resistance Sign,RS)等定位方法的優(yōu)勢和缺陷。在此基礎上,文章從電網(wǎng)故障分析入手,運用線性電路疊加定理,提出新的基于擾動功率極性的暫降源定位方法:以監(jiān)測裝置內電壓電流互感器同極性方向為參考方向,若監(jiān)測到的擾動功率為正,則電壓暫降源位于監(jiān)測裝置的上游;反之,若監(jiān)測到的擾動功率為負,則電壓暫降源位于下游。在雙端供電系統(tǒng)、輻射式電網(wǎng)、IEEE9節(jié)點標準環(huán)形電網(wǎng)等網(wǎng)架結構下仿真測試包括單相接地故障、兩相接地故障、相間短路故障和三相短路在內的各種短路故障擾動以及大電機啟動、電容投切等擾動類型,驗證了該方法的準確性。文章最后設計了電壓暫降源在線定位與監(jiān)測裝置及配電網(wǎng)擾動定位與電能質量在線監(jiān)測分析系統(tǒng),并通過實驗證明本文方法適用于包括輻射式電網(wǎng)、雙端供電網(wǎng)以及環(huán)形電網(wǎng)在內的各種網(wǎng)架結構。
[Abstract]:The rapid development of modern power electronic technology, a large number of application of the sensitive power load, power load and sensitive to power quality requirements compared to the traditional load is higher, the resulting user power quality problems become more and more frequent complaints, including complaints 80% voltage sag events. Voltage sag has become the most dynamic power quality problems. Serious. The voltage sag source location, is to determine which side is located in the sag source monitoring device. The accurate location of voltage sag source can effectively define the voltage sags in distribution network caused by the responsible party, for electricity, both to provide theoretical basis to solve the contradiction, at the same time, the voltage sag source location can be the effective evaluation of the weak link of the distribution network, to provide guidance for power grids. Firstly, this paper takes Xuyi County Liang Ying substation power distribution network as an example, all kinds of faults of 20K V distribution network disturbance etc., The spread of domain and the effect of voltage sags, to provide advice on the harm of distribution network is effectively reduced voltage sag. Secondly, based on the detailed introduction of the existing sag source location method, modeling simulation and analysis of the existing 5 kinds of positioning methods, pointed out that including the disturbance energy and disturbance power method (Disturbance Energy and Power. DEP), current real polarity method (Real Current Component, RCC), the system trajectory slope method (Slope of System Trajectory, SST), distance (Distance Relay, impedance relay method DR) and the equivalent impedance polarity method (Resistance Sign RS) the advantages and disadvantages of other positioning methods. On the basis of this paper, from the analysis of the fault of circuit using linear superposition theorem, put forward a new method of sag source location disturbance power polarity based on monitoring device voltage and current transformer polarity direction for the reference direction, if detected The disturbance power is upstream of the voltage sag source in the monitoring device; on the other hand, if the disturbance power monitoring is negative, then the voltage sag source located downstream. In the double end power supply system, radiant power grid, simulation test of IEEE9 node standard circular grid grid structure including single phase grounding fault, two-phase grounding fault, fault phase and three-phase short circuit fault disturbance and large motor starting, capacitor switching disturbance type, verified the accuracy of the method. Finally the design of voltage sag source location and online monitoring device and distribution network disturbance localization and on-line monitoring of power quality analysis system, and through experiments to prove that this method is applicable to include radiation power grid, power supply network and double end ring grid, all kinds of network structure.
【學位授予單位】:中國礦業(yè)大學
【學位級別】:碩士
【學位授予年份】:2016
【分類號】:TM714.2
【相似文獻】
相關期刊論文 前10條
1 鐘慶;易楊;武志剛;張堯;羅杰;;電力用戶電壓暫降問題分析與仿真[J];電力系統(tǒng)及其自動化學報;2008年06期
2 陳鐵敏;楊洪耕;楊林;;基于最大熵原理的電壓暫降評估[J];現(xiàn)代電力;2008年03期
3 袁媛;吳丹岳;林焱;徐永海;章雪萌;;電壓暫降評估體系研究[J];電網(wǎng)技術;2010年06期
4 全惠敏;戴瑜興;;電壓暫降的改進S變換分析與分類[J];湖南大學學報(自然科學版);2011年03期
5 舒曉玲;牟常健;;電壓暫降及機場電網(wǎng)對電壓暫降的應對措施[J];電氣制造;2011年10期
6 曹云軒;張捷;許宏;;一起電壓暫降過程的案例分析[J];華中電力;2012年03期
7 宋文生;柴小馬;馮建奇;;電壓暫降分析及防范措施[J];科技視界;2012年30期
8 張少強;;電壓暫降問題初探[J];可編程控制器與工廠自動化;2013年11期
9 張子林;;電壓暫降分析及解決方案[J];技術與市場;2013年12期
10 劉旭娜;肖先勇;汪穎;;電壓暫降嚴重程度及其測度、不確定性評估方法[J];中國電機工程學報;2014年04期
相關會議論文 前10條
1 曹云軒;唐林;馮浩;申玉梅;;企業(yè)生產(chǎn)受電壓暫降影響原因及解決方案[A];2013年中國電機工程學會年會論文集[C];2013年
2 季萬豐;;油田電網(wǎng)電壓暫降問題分析及對策[A];山東省石油學會油田電力、通信及自動化技術研討會優(yōu)秀工程技術論文集[C];2009年
3 徐育福;蔡金錠;李天友;;電壓暫降檢測算法分析[A];中國高等學校電力系統(tǒng)及其自動化專業(yè)第二十四屆學術年會論文集(下冊)[C];2008年
4 陳衛(wèi)東;;基于參數(shù)估計的電壓暫降區(qū)間評估[A];第二屆全國電能質量學術會議暨電能質量行業(yè)發(fā)展論壇論文集[C];2011年
5 于希娟;;照明燈具對電壓暫降敏感性研究[A];第二屆全國電能質量學術會議暨電能質量行業(yè)發(fā)展論壇論文集[C];2011年
6 陳瑞;韓民曉;姚蜀軍;汪全濤;丁冉峰;;雙回供電系統(tǒng)電壓暫降相關性研究[A];2006中國電工技術學會電力電子學會第十屆學術年會論文摘要集[C];2006年
7 尹虎臣;劉建偉;韓民曉;林少伯;李文濤;;基于超級電容器儲能的電壓暫降治理裝置的研發(fā)[A];第二屆全國電能質量學術會議暨電能質量行業(yè)發(fā)展論壇論文集[C];2011年
8 冷冰;張峰;高天德;;小波分析在電壓暫降檢測算法中的應用研究[A];第三屆上海——西安聲學學會學術會議論文集[C];2013年
9 徐攀峰;周勇;;檢測電壓暫降特征量的有效值算法[A];第十屆中國科協(xié)年會科技創(chuàng)新與工業(yè)強市戰(zhàn)略論壇論文匯編[C];2008年
10 曹立志;王小君;和敬涵;梁啟權;薄志謙;Tony Yip;;基于DSP的電壓暫降檢測方法研究[A];中國智能電網(wǎng)學術研討會論文集[C];2011年
相關重要報紙文章 前2條
1 通訊員 陸震;杜絕安全隱患 維護機場穩(wěn)定[N];中國民航報;2009年
2 郭清梅 吳麗芳;電壓暫降與短時中斷標準研究項目順利通過評審[N];國家電網(wǎng)報;2009年
相關博士學位論文 前3條
1 楊曉東;電壓暫降的隨機預估及其經(jīng)濟管理方法研究[D];華北電力大學(河北);2010年
2 李希年;電壓暫降導致的電動機動態(tài)過程的研究[D];中國礦業(yè)大學(北京);2014年
3 雷之力;微網(wǎng)諧波振及電壓暫降的評估與控制[D];華北電力大學(北京);2011年
相關碩士學位論文 前10條
1 袁媛;電壓暫降的隨機預估和指標研究[D];華北電力大學(北京);2010年
2 丁寧;電壓暫降源的識別和暫降檢測算法研究[D];華北電力大學(北京);2010年
3 劉配配;電壓暫降特征值提取及其影響[D];華南理工大學;2011年
4 肖玉龍;電壓暫降檢測及其補償方法的研究[D];天津大學;2006年
5 丁雪霜;電壓暫降擾動源辨識的仿真研究[D];華北電力大學(河北);2007年
6 鄭立;邢臺電網(wǎng)電壓暫降的統(tǒng)計分析與預測[D];華北電力大學(河北);2007年
7 葉根富;小波包分析在電壓暫降檢測中的應用[D];華北電力大學(河北);2008年
8 李杰;基于虛擬儀器的電壓暫降分析系統(tǒng)[D];華北電力大學;2011年
9 孫維蒙;基于智能學習算法的電壓暫降影響評估與定位研究[D];浙江師范大學;2011年
10 魏榮進;電壓暫降檢測與擾動源辨識方法的分析與研究[D];湖南大學;2012年
,本文編號:1379927