容積CT數(shù)字減影血管造影和三維數(shù)字減影血管造影診斷顱內(nèi)動(dòng)脈瘤的價(jià)值比較
本文選題:顱內(nèi)動(dòng)脈瘤 + 容積CT數(shù)字減影血管造影 ; 參考:《中國(guó)老年學(xué)雜志》2015年03期
【摘要】:目的對(duì)比容積CT數(shù)字減影血管造影(VCTDSA)和三維數(shù)字減影血管造影(3D-DSA)在顱內(nèi)動(dòng)脈瘤診斷中的價(jià)值。方法疑似顱內(nèi)動(dòng)脈瘤患者74例,男31例,女43例,平均72.3歲。均行VCTDSA和3D-DSA檢查,兩位評(píng)價(jià)者分析此兩項(xiàng)檢查的影像資料,記錄動(dòng)脈瘤檢出的個(gè)數(shù)、部位及大小,并評(píng)價(jià)VCTDSA的診斷效能(包括敏感性、特異性、陽(yáng)性預(yù)測(cè)值和陰性預(yù)測(cè)值)及兩種技術(shù)診斷動(dòng)脈瘤的一致性。結(jié)果 3D-DSA檢出動(dòng)脈瘤94個(gè),VCTDSA檢出93個(gè)(評(píng)價(jià)者A檢出93個(gè),評(píng)價(jià)者B 92個(gè));評(píng)價(jià)者A檢出全部動(dòng)脈瘤以及檢出3 mm動(dòng)脈瘤的敏感性和陰性預(yù)測(cè)值較評(píng)價(jià)者B高,而兩者檢出≥3 mm動(dòng)脈瘤的敏感性和特異性均為100%;在檢出動(dòng)脈瘤個(gè)數(shù)、部位和大小三方面,3D-DSA和VCTDSA有很好的評(píng)價(jià)者間的一致性。結(jié)論 VCTDSA的動(dòng)脈瘤檢出效能與3D-DSA相當(dāng),可以作為顱內(nèi)動(dòng)脈瘤影像診斷的準(zhǔn)確方法。
[Abstract]:Objective to compare the value of volume CT digital subtraction angiography (VCTDSA) and three-dimensional digital subtraction angiography (3D-DSA) in the diagnosis of intracranial aneurysms. Methods 74 cases of suspected intracranial aneurysms, 31 males and 43 women, averaging 72.3 years old. All of them were examined by VCTDSA and 3D-DSA, and two of the two patients were analyzed the two examination images and recorded the aneurysm examination. The number, location, size and diagnostic efficacy of VCTDSA (including sensitivity, specificity, positive predictive value and negative predictive value) and the consistency of two kinds of aneurysms were evaluated. Results 3D-DSA detected 94 aneurysms and 93 VCTDSA (93 of the evaluators were detected by A and 92 of the evaluators); the evaluator A detected all the aneurysms and detected 3 of the aneurysms. The sensitivity and negative predictive value of MM aneurysm were higher than that of the evaluator B, and the sensitivity and specificity of both of them to 3 mm aneurysms were 100%. In detecting the number of aneurysms, location and size three, 3D-DSA and VCTDSA had a good consistency between the evaluators. Conclusion the detection efficiency of the aneurysm of VCTDSA is equivalent to that of 3D-DSA and can be used as a intracranial aneurysm. An accurate method of imaging diagnosis of aneurysm.
【作者單位】: 重慶醫(yī)科大學(xué)附屬第一醫(yī)院核醫(yī)學(xué)科;重慶醫(yī)科大學(xué)第一醫(yī)院放射科;
【基金】:重慶市衛(wèi)生局醫(yī)學(xué)科研項(xiàng)目(2009-2-315,2010-2-444)
【分類號(hào)】:R743;R816.1
【參考文獻(xiàn)】
相關(guān)期刊論文 前2條
1 呂發(fā)金;張麗娟;房文皓;李琦;李詠梅;謝鵬;;減影CTA和64層VCTDSA對(duì)顱內(nèi)動(dòng)脈瘤診斷價(jià)值的比較[J];重慶醫(yī)科大學(xué)學(xué)報(bào);2008年10期
2 呂發(fā)金;謝鵬;羅天友;張志偉;何怡紅;孫曉川;牟君;方維東;;數(shù)字減影CT血管成像在蛛網(wǎng)膜下腔出血診斷中的價(jià)值[J];中國(guó)醫(yī)學(xué)影像技術(shù);2007年01期
【共引文獻(xiàn)】
相關(guān)期刊論文 前10條
1 寧殿秀;李智勇;管秀科;劉愛(ài)連;伍建林;郎志謹(jǐn);;數(shù)字減影CT血管成像在血管性病變?cè)\斷中的應(yīng)用價(jià)值[J];實(shí)用放射學(xué)雜志;2008年12期
2 鄧小林;謝惠;周幫建;吳紹全;趙榮;覃川;;128層螺旋CT血管成像在自發(fā)性蛛網(wǎng)膜下腔出血病因診斷中的價(jià)值[J];陜西醫(yī)學(xué)雜志;2012年08期
3 劉元斌;諶業(yè)榮;周恩漢;;64層螺旋CT數(shù)字減影血管成像應(yīng)用影響因素探討[J];山西醫(yī)藥雜志;2012年09期
4 張龍;張s,
本文編號(hào):1981844
本文鏈接:http://www.sikaile.net/yixuelunwen/yundongyixue/1981844.html