肝素連接苯丙氨酸血液凈化材料去除內(nèi)毒素的研究
本文選題:內(nèi)毒素 + 肝素 ; 參考:《中國生物醫(yī)學工程學報》2013年03期
【摘要】:以氯甲基樹脂為基底材料,肝素為連接臂連接配基苯丙氨酸,合成了一種安全無毒的新型內(nèi)毒素吸附劑。本課題通過改變不同的反應物用量、反應時間和pH值尋找出最佳實驗條件,同時對合成好的肝素-苯丙氨酸吸附劑在不同介質(zhì)(水及血漿)、不同內(nèi)毒素初始濃度、不同時長條件下的吸附性能進行了研究,并對血液相容性進行了評價。在水以及兔子血漿的體外灌流實驗中,2 h以內(nèi)可將內(nèi)毒素含量降至較低水平,最高清除率水中可達79%,血漿中為72%,且對血液中的其他物質(zhì)含量影響較小(均小于10%),血液相容性良好。
[Abstract]:A new safe and nontoxic endotoxin adsorbent was synthesized by using chloromethyl resin as substrate and heparin as ligand linked with phenylalanine. In this study, the optimal experimental conditions were obtained by changing the amount of reactants, reaction time and pH value, and the initial concentration of endotoxin in different media (water and plasma, different endotoxin) was obtained for heparin-phenylalanine adsorbent. The adsorption performance was studied and the blood compatibility was evaluated. In the in vitro perfusion experiment of water and rabbit plasma, endotoxin content could be reduced to a lower level within 2 hours. The highest clearance rate was 79% in water and 722 in plasma, and had little effect on other substances in blood (all less than 10%), and had good blood compatibility.
【作者單位】: 重慶大學生物流變學重點實驗室;
【基金】:重慶市項目(cstc2011ac5193)
【分類號】:R318.08
【相似文獻】
相關期刊論文 前10條
1 吳洪坤;何德沛;溫劍虎;;戊二醛結(jié)合肝素鞣制牛頸靜脈帶瓣管道抗鈣化的實驗研究[J];重慶醫(yī)學;2008年07期
2 張飛鴻;王聰;周怡;;血液透析機消毒作用的探討[J];中國醫(yī)學裝備;2010年03期
3 項昭保,霍丹群,候長軍,蔡紹皙;肝素化抗凝血生物材料的研究[J];現(xiàn)代醫(yī)學儀器與應用;2002年04期
4 王學寧;陳長志;楊岷;Y.John Gu;;小口徑異種血管作為冠狀動脈旁路移植術(shù)橋材料的研究[J];中國胸心血管外科臨床雜志;2006年04期
5 宋杰;吳熹;黃楠;徐標;景鳳娟;陳俊英;冷永祥;楊蘋;王進;孫鴻;趙安莎;;纖維蛋白原與吸附白蛋白、肝素的新型血管支架材料氧化鈦的血液相容性[J];生物醫(yī)學工程學雜志;2007年05期
6 馬艷;岳秀麗;劉萌;彭濤;劉紹琴;戴志飛;;共價交聯(lián)的肝素/海藻酸鹽水凝膠表面修飾膨體聚四氟乙烯人工血管(英文)[J];中國組織工程研究與臨床康復;2008年10期
7 丁洋;萬圣云;;肝素對大鼠骨髓基質(zhì)干細胞來源的血管內(nèi)皮細胞貼附ePTFE影響的實驗研究[J];安徽醫(yī)藥;2008年08期
8 王為超;胡月晗;歐來良;孔德領;俞耀庭;;一種類風濕因子血液凈化吸附劑的制備與性能評價[J];中國生物醫(yī)學工程學報;2009年04期