體表電極代替多導食道電極測定慢性阻塞性肺疾病患者呼吸中樞驅動的可行性
發(fā)布時間:2018-06-15 23:22
本文選題:呼吸中樞驅動 + 等二氧化碳高通氣; 參考:《實用醫(yī)學雜志》2017年15期
【摘要】:目的探討體表電極代替多導食道電極測定慢性阻塞性肺疾病(慢阻肺)患者呼吸中樞驅動的可行性。方法研究對象為呼吸科門診29例穩(wěn)定期中重度慢阻肺患者,均為男性,平均年齡(65.6±7.2)歲。采用體表電極和多導食道電極同時記錄患者吸入支氣管舒張劑前后靜息狀態(tài)和等二氧化碳高通氣(MIV)時膈肌肌電和肺通氣量的變化,比較兩種方法測定的呼吸中樞驅動的差異。采用重復測量數(shù)據(jù)的方差分析,兩兩比較用最小LSD檢驗,相關分析采用Pearson檢驗。結果吸入支氣管舒張劑后,患者靜息和MIV時的肺通氣量增加,體表電極和多導食道電極測定的呼吸中樞驅動均同步降低,呈顯著相關(r=0.660,P0.01)。結論采取措施盡可能減少體表電極干擾的情況下,體表電極可以代替多導食道電極測定慢阻肺患者的呼吸中樞驅動。
[Abstract]:Objective to study the feasibility of using body surface electrode instead of multichannel esophageal electrode to measure respiratory center drive in patients with chronic obstructive pulmonary disease (COPD). Methods A total of 29 moderate and severe COPD patients (mean age: 65.6 鹵7.2) years were enrolled in this study. The changes of diaphragm electromyography and pulmonary ventilation volume during inhalation of bronchodiastolic agents and iso-carbon dioxide hyperventilation (MIV) were recorded by body surface electrode and multichannel electrode simultaneously. The difference of respiratory center drive between the two methods was compared. The variance analysis of repeated measurement data, the minimum LSD test for pairwise comparison, and Pearson test for correlation analysis were used. Results after inhaling bronchodiastolic agent, the pulmonary ventilation volume increased at rest and MIV, and the respiratory center drive measured by body surface electrode and multichannel esophagus electrode decreased synchronously, and there was a significant correlation between the lung ventilation volume and the respiratory center drive measured by body surface electrode and multichannel esophagus electrode. Conclusion when some measures are taken to minimize the interference of body surface electrodes, body surface electrodes can replace multichannel esophageal electrodes to determine the respiratory center drive in patients with chronic obstructive pulmonary disease.
【作者單位】: 廣州市番禺區(qū)中心醫(yī)院呼吸內科;南方醫(yī)科大學珠江醫(yī)院呼吸內科;廣州醫(yī)科大學附屬第一醫(yī)院呼吸內科;
【基金】:廣州市科技攻關專項基金資助(編號:201300000171) 廣東省科技計劃項目(編號:粵科[2013]137)
【分類號】:R563.9
【相似文獻】
相關期刊論文 前10條
1 萬桂敏,張麗虹;用平板氟電極測定微量血清氟[J];中國地方病防治雜志;1990年06期
2 張安靖;氟電極測定茶葉中氟的質量內控實驗[J];預防醫(yī)學情報雜志;2003年06期
3 陸桂祥;;用氨選擇性電極測定尿(血)中尿素及氨[J];國外醫(yī)學.臨床生物化學與檢驗學分冊;1982年01期
4 徐鳳儀;碘離子選擇電極測定食鹽中的碘[J];中國地方病學雜志;1984年01期
5 白文林;胡守珍;;銀離子電極測定水中微量氰[J];鐵道勞動衛(wèi)生通訊;1984年02期
6 彭應馥;用硫離子電極測定水及廢水中硫化物[J];環(huán)境與健康雜志;1987年01期
7 蔣復;馬一平;;氯離子選擇電極測定輸液中氯化鈉的含量[J];化學傳感器;1985年01期
8 余月仙;氰離子選擇電極測定酒中氰化物[J];浙江預防醫(yī)學;1999年02期
9 陳執(zhí)中;胥保生;姜超;;塑料膜電極在藥物分析中的應用[J];中成藥研究;1981年07期
10 廖麗華;;銀離子電極測定苯妥英鈉含量[J];化學傳感器;1989年01期
相關會議論文 前2條
1 舒菲菲;賈金平;;化學滴液電極測定水中的pH值[A];第五屆全國環(huán)境化學大會摘要集[C];2009年
2 王s,
本文編號:2024096