基于CFD數(shù)值模擬的外取熱器管束爆裂原因分析
發(fā)布時間:2018-07-09 19:42
本文選題:外取熱器 + 管束爆裂 ; 參考:《現(xiàn)代化工》2017年03期
【摘要】:某廠催化裂化裝置外取熱器管束出氣管根部與三通連接位置接連發(fā)生爆裂,此處發(fā)生爆裂尚屬首次。為找出管束爆裂的主要原因,運用了計算流體力學(xué)軟件Fluent中的DPM模型對該處氣液兩相流場、管壁的沖蝕情況及水蒸汽中水滴分率對管壁沖蝕的影響進行了數(shù)值模擬。結(jié)果表明,管束爆裂處混合流體速度最大,冷凝水滴濃度最高,致使沖刷最嚴重,且水滴的分率越大,沖刷越嚴重。腐蝕及沖刷的交替惡性循環(huán)是造成外取熱器管束爆裂的主要原因。
[Abstract]:In a FCCU, the connection position between the trachea root and the three-way connection of the tubing bundle of the external heat extractor in a FCCU has burst successively, and it is the first time that the burst occurs here. In order to find out the main reasons of pipe burst, the DPM model of CFD software fluent was used to simulate the gas-liquid two-phase flow field, the erosion of pipe wall and the effect of water droplet rate in water vapor on the erosion of pipe wall. The results show that the maximum velocity of mixing fluid and the highest concentration of condensate water droplet in the burst of tube bundle result in the most serious scour and the bigger the fraction of water droplet is the more serious the scour is. The alternating vicious circle of corrosion and scour is the main cause of tube burst.
【作者單位】: 西安石油大學(xué)機械工程學(xué)院;
【分類號】:TE965
【相似文獻】
相關(guān)期刊論文 前10條
1 宋賢生;劉全楨;宮宏;秦汝祥;戴廣龍;;大型罐區(qū)油氣擴散規(guī)律的CFD數(shù)值模擬研究[J];中國安全生產(chǎn)科學(xué)技術(shù);2008年02期
2 翟俊霞,涂善東;復(fù)雜管狀構(gòu)件中流體的CFD數(shù)值模擬[J];化工時刊;2005年09期
3 沈艷濤;于建國;;有毒有害氣體泄漏的CFD數(shù)值模擬(Ⅰ)模型建立與校驗[J];化工學(xué)報;2007年03期
4 譚志洪;高洋洋;劉麗冰;王作杰;;大型過程裝備CFD數(shù)值模擬及分析[J];水泥;2012年01期
5 陳翼;張林進;葉旭初;;射流混合器內(nèi)氣體湍流擴散過程的CFD數(shù)值模擬與實驗研究[J];過程工程學(xué)報;2007年05期
6 崔大椺;;銅精煉爐的CFD數(shù)值模擬優(yōu)化[J];中國有色冶金;2013年02期
7 張海茹;楊宏e,
本文編號:2110453