城市供水管網(wǎng)水源切換模擬及黃水控制措施研究
發(fā)布時(shí)間:2018-08-07 12:58
【摘要】:針對(duì)Z市未來(lái)水源切換期間可能發(fā)生的黃水現(xiàn)象,通過(guò)建立小區(qū)試驗(yàn)?zāi)P?研究了管網(wǎng)中總鐵、溶解氧和硫酸鹽等水質(zhì)參數(shù)在換水期間的變化規(guī)律。研究結(jié)果表明:硫酸鹽濃度可以作為整個(gè)水源切換過(guò)程的指示性指標(biāo),該市主要管網(wǎng)水源切換過(guò)程的終點(diǎn)時(shí)間約30h,小區(qū)管道在換水期間將發(fā)生鐵超標(biāo)現(xiàn)象,通過(guò)增大管道內(nèi)余氯濃度至0.4mg/L以上,控制管網(wǎng)溶解氧水平在4.50mg/L以上,可在換水7d后有效緩解黃水現(xiàn)象。
[Abstract]:In view of the yellow water phenomenon which may occur during the future water source switching in Z city, the variation of total iron, dissolved oxygen and sulfate in the pipe network during the period of water exchange is studied by establishing the plot test model. The results show that the sulfate concentration can be used as an indicator for the whole process of water source switching. The end point of the water source switching process of the main pipe network in the city is about 30 hours, and the phenomenon of iron exceeding the standard will occur in the pipeline of the residential area during the period of water exchange. By increasing the residual chlorine concentration above 0.4mg/L and controlling the dissolved oxygen level of the pipe network above 4.50mg/L, the yellow water phenomenon can be effectively alleviated after 7 days of water exchange.
【作者單位】: 鄭州自來(lái)水投資控股有限公司;
【基金】:鄭州市技術(shù)研究與開(kāi)發(fā)支持重點(diǎn)科技攻關(guān)項(xiàng)目(121PZDGG320) 鄭州市民生科技進(jìn)步工程項(xiàng)目(131PZDGC143) 國(guó)家水體污染控制與治理科技重大專(zhuān)項(xiàng)(2012ZX07404-004)
【分類(lèi)號(hào)】:TU991
[Abstract]:In view of the yellow water phenomenon which may occur during the future water source switching in Z city, the variation of total iron, dissolved oxygen and sulfate in the pipe network during the period of water exchange is studied by establishing the plot test model. The results show that the sulfate concentration can be used as an indicator for the whole process of water source switching. The end point of the water source switching process of the main pipe network in the city is about 30 hours, and the phenomenon of iron exceeding the standard will occur in the pipeline of the residential area during the period of water exchange. By increasing the residual chlorine concentration above 0.4mg/L and controlling the dissolved oxygen level of the pipe network above 4.50mg/L, the yellow water phenomenon can be effectively alleviated after 7 days of water exchange.
【作者單位】: 鄭州自來(lái)水投資控股有限公司;
【基金】:鄭州市技術(shù)研究與開(kāi)發(fā)支持重點(diǎn)科技攻關(guān)項(xiàng)目(121PZDGG320) 鄭州市民生科技進(jìn)步工程項(xiàng)目(131PZDGC143) 國(guó)家水體污染控制與治理科技重大專(zhuān)項(xiàng)(2012ZX07404-004)
【分類(lèi)號(hào)】:TU991
【參考文獻(xiàn)】
相關(guān)期刊論文 前2條
1 王洋;張曉健;陳超;潘安君;徐揚(yáng);廖平安;張素霞;顧軍農(nóng);;水源切換引起給水管網(wǎng)黃水問(wèn)題原因分析[J];環(huán)境科學(xué);2009年12期
2 周全;韓珀;徐娟;蘇U,
本文編號(hào):2170090
本文鏈接:http://www.sikaile.net/kejilunwen/sgjslw/2170090.html
最近更新
教材專(zhuān)著