表面增強拉曼光譜技術在汞離子檢測中應用研究
本文關鍵詞:表面增強拉曼光譜技術在汞離子檢測中應用研究 出處:《合肥工業(yè)大學》2016年碩士論文 論文類型:學位論文
更多相關文章: 表面增強拉曼光譜 汞離子 核酸適配體 金納米粒子 增敏 銀納米粒子
【摘要】:重金屬汞離子(Hg2+)是對人類和動植物具有很大毒害作用的金屬元素,對人的腎、肝臟等組織以及神經(jīng)系統(tǒng)等都可產生嚴重的損害作用,直接威脅了食品和環(huán)境安全。因此,建立快速、靈敏、便捷的汞離子檢測方法對保護人類健康具有重要作用。本文所介紹了以下三種檢測方法:(1)基于側向層析技術的表面增強拉曼光譜Hg2+檢測法本文基于經(jīng)典的T-Hg2+-T識別系統(tǒng),在表面標記了拉曼信號分子的金納米粒子(AuNPs)表面組裝了富含T堿基Hg2+核酸適配體,利用T-Hg2+-T錯配與同樣富含T堿基的測試線(T線)上標記的核酸探針結合而被捕獲顯線,通過堿基互補配對被標記在質控線(C線)上的核酸探針捕獲顯線,通過肉眼觀察顯線強度初步定性分析待測體系中Hg2+濃度,而通過拉曼光譜分析,對肉眼分辨不出來的范圍也能檢測出其信號強度,從而在層析技術的基礎上提高了檢測靈敏度,通過優(yōu)化選擇以Au@Ag核殼結構作為基底材料,比單純的(AuNPs)作為基底拉曼信號增強的效果好,最終靈敏度可達到0.1 ppb。(2)傳統(tǒng)型表面增強拉曼光譜Hg2+檢測方法本方法也是建立在Hg2+核酸適配體的基礎上,在表面標記了拉曼信號分子的AuNPs上組裝Hg2+核酸適配體,通過識別Hg2+后以T-Hg2+-T的結合拉近金納米粒子之間距離,粒子之間形成熱點,該位置處電磁場強度較強,處于熱點區(qū)域的拉曼信號分子的信號也有所提高,在有Hg2+存在時進行拉曼信號強度檢測,使其檢測靈敏度遠遠高于比色法,拉曼檢測的靈敏度為0.01nM,在汞離子濃度為10-11-10-8M時,拉曼信號強度與汞離子濃度的對數(shù)呈現(xiàn)良好線性關系。(3)信號增敏型表面增強拉曼光譜Hg2+檢測方法在傳統(tǒng)拉曼檢測的基礎上,通過一對相互互補的寡核苷酸探針,在AuNPs表面再組裝小粒徑的銀納米粒子(AgNPs),增加并增強兩金納米粒子之間熱點處電磁場強度,使拉曼信號分子信號進一步提高而達到增敏效果,對兩種納米粒子比例以及互補探針濃度優(yōu)化,增敏后對汞的檢測靈敏度提高到0.01 pM,在10-12-10-8M的濃度范圍內,拉曼信號強度與汞離子濃度的對數(shù)也是呈良好線性。
[Abstract]:Hg2) is a metal element that has a great toxic effect on human beings, animals and plants. It can cause serious damage to human kidney, liver and nervous system. A direct threat to food and environmental safety. Therefore, the establishment of fast, sensitive. The convenient method of mercury ion detection plays an important role in the protection of human health. This paper introduces the following three detection methods: 1). Surface enhanced Raman Spectroscopy (Hg2) Detection based on Lateral Chromatography this paper is based on the classical T-Hg2-T recognition system. On the surface of au nanoparticles labeled with Raman signal molecules, the aptamers of Hg2 nucleic acid rich in T bases were assembled. The T-Hg2-T mismatch was combined with the labeled nucleic acid probe on the test line, which is also rich in T bases. The nucleic acid probe labeled on the quality control line C line by complementary pair of base pairs was used to capture the display line. The Hg2 concentration in the system was analyzed qualitatively by observing the intensity of the display line with naked eye, and the Raman spectrum was used to analyze it. The signal intensity can also be detected for the range which can not be distinguished by the naked eye, so the detection sensitivity is improved on the basis of chromatographic technology, and the Au@Ag core-shell structure is selected as the substrate material by optimizing the selection. Compared with the pure AuNPs, the enhancement effect of the substrate Raman signal is better than that of the pure AuNPs. The traditional surface-enhanced Raman spectroscopy (Hg2) method is based on the aptamer of Hg2 nucleic acid. The aptamer of Hg2 nucleic acid was assembled on the surface of AuNPs labeled with Raman signal molecule, and the distance between gold nanoparticles was reduced by T-Hg2-T binding after Hg2 recognition. A hot spot is formed between the particles, and the intensity of the electric magnetic field is strong at this position, and the signal of Raman signal molecule in the hot spot region is also improved. The intensity of the Raman signal is detected in the presence of Hg2. The sensitivity of the method is much higher than that of colorimetric method. The sensitivity of Raman detection is 0.01nM, when the concentration of mercury ion is 10-11-10-8M. There is a good linear relationship between the intensity of Raman signal and the logarithm of mercury ion concentration. The signal sensitized surface-enhanced Raman spectroscopy (Hg2) detection method is based on the traditional Raman detection method. A pair of complementary oligonucleotide probes were used to reassemble small silver nanoparticles (AgNPs) on the surface of AuNPs to increase and enhance the electric field intensity at the hot spot between the two gold nanoparticles. The ratio of two nanoparticles and the concentration of complementary probe were optimized to increase the sensitivity of mercury detection to 0.01 pm. In the range of 10-12 ~ (-8) M, the logarithm of Raman signal intensity and mercury ion concentration is also linear.
【學位授予單位】:合肥工業(yè)大學
【學位級別】:碩士
【學位授予年份】:2016
【分類號】:TS207.3;O657.37
【相似文獻】
相關期刊論文 前10條
1 羅欣,劉芳,周揚,賀啟環(huán);杯芳烴衍生物的合成及其對溶液中汞離子的萃取[J];環(huán)境衛(wèi)生工程;2004年01期
2 劉占才;孔祥會;郭彥玲;郭春麗;;不同濃度汞離子暴露下草魚(Ctenopharyngodon idella)器官組織中酸性磷酸酶活性變化[J];河南師范大學學報(自然科學版);2007年03期
3 陳述;范亞;葉麗英;龍云飛;;硫離子修飾的金納米棒用于汞離子檢測[J];光譜實驗室;2011年04期
4 陳昌倫;張青;吳狄;;一種用于水樣檢測的快速汞離子熒光傳感器[J];分析試驗室;2013年07期
5 吳小麗;賴金平;趙一兵;;汞離子的高靈敏度裸眼識別和熒光傳感探針[J];高等學;瘜W學報;2012年04期
6 李立冬;于涼云;吳玉芹;張奇;;汞離子熒光傳感器研究新進展[J];河南化工;2012年21期
7 龍云飛;;水溶性硫化鉛納米粒子的合成及應用于汞離子檢測[J];光譜實驗室;2011年03期
8 周宗益;銀、汞離子的快速鑒別法[J];達縣師專學報;1994年02期
9 徐海云;劉起峰;趙文獻;劉瑛;;基于氟硼二吡咯染料的汞離子熒光分子探針的合成與光譜性質(英文)[J];無機化學學報;2012年07期
10 沙兆林;聚吡咯膜對汞離子富集作用的研究[J];南通工學院學報(自然科學版);2002年02期
相關會議論文 前10條
1 吳小麗;賴金平;趙一兵;;汞離子的高靈敏度光學傳感[A];第十屆中國化學會分析化學年會暨第十屆全國原子光譜學術會議論文摘要集[C];2009年
2 劉衛(wèi)敏;吳加勝;汪鵬飛;;可逆識別汞離子的熒光化學傳感分子[A];中國化學會第十屆全國發(fā)光分析學術研討會論文集[C];2011年
3 王勇;楊帆;楊秀榮;;利用銀納米探針和富T脫氧核酸無標比色測定汞離子[A];第十屆中國化學會分析化學年會暨第十屆全國原子光譜學術會議論文摘要集[C];2009年
4 王如勇;陳城;王振宇;傅南雁;;一種基于方酸菁的選擇性比色識別汞離子的化學傳感器[A];中國化學會第27屆學術年會第06分會場摘要集[C];2010年
5 周硼;孟慶濤;宋春霞;趙秀文;;熒光探針法測定水環(huán)境中汞離子的研究[A];第五屆全國環(huán)境化學大會摘要集[C];2009年
6 金麗花;尚利;李敬;董紹俊;;生物分子穩(wěn)定貴金屬納米簇在熒光檢測汞離子的應用[A];中國化學會第27屆學術年會第09分會場摘要集[C];2010年
7 馬俊福;;人體臟器中汞離子含量的測定[A];第五次全國法醫(yī)學術交流會論文集[C];1996年
8 楊楨;李襄宏;程新建;張愛清;;基于聚氨酯膜的汞離子“試紙”的制備[A];2013年全國高分子學術論文報告會論文摘要集——主題F:功能高分子[C];2013年
9 張志君;王慧;張衡益;劉育;;香豆素修飾氮雜15冠5對汞離子的選擇性傳感[A];全國第十六屆大環(huán)化學暨第八屆超分子化學學術討論會論文摘要集[C];2012年
10 史兵兵;張有明;張鵬;魏太保;;雙通道Hg~(2+)化學傳感器的合成與研究[A];全國第十六屆大環(huán)化學暨第八屆超分子化學學術討論會論文摘要集[C];2012年
相關博士學位論文 前3條
1 劉寶玉;以二氧化硅粒子為基體的熒光共振能量轉移體系在汞離子比率檢測中的應用[D];華南理工大學;2011年
2 李洪偉;基于磺酰胺基團的汞離子熒光探針的設計、合成及識別機理研究[D];吉林大學;2009年
3 張q,
本文編號:1387089
本文鏈接:http://www.sikaile.net/kejilunwen/huaxue/1387089.html