【摘要】:隨著高精度同位素測量技術(shù)的發(fā)展,雙稀釋劑方法被證明是很多同位素體系測量的必要方法。盡管雙稀釋劑方法的原理和計算過程在多篇文獻(xiàn)中已有介紹,但雙稀釋劑本身的測量和校正方法還沒有被系統(tǒng)地討論過。本文從介紹同位素質(zhì)量分餾定律入手,簡明闡述了雙稀釋劑測量原理并推導(dǎo)了雙稀釋劑計算公式及計算方法。同時進(jìn)一步討論了雙稀釋劑校正方法與其對同位素測量結(jié)果的影響,提出了雙稀釋劑方法的完整公式,以及相應(yīng)的雙稀釋劑誤差傳遞推導(dǎo)過程。
[Abstract]:With the development of high precision isotope measurement technology, double diluent method has been proved to be necessary for many isotopic systems. Although the principle and calculation process of the double diluent method have been introduced in many literatures, the measurement and correction methods of the double diluent itself have not been systematically discussed. Starting with the introduction of isotopic mass fractionation law, the measuring principle of double diluent and the calculation formula and method of double diluent are presented in this paper. At the same time, the correction method of double diluent and its influence on isotopic measurement results are discussed. The complete formula of double diluent method and the derivation process of error transfer of double diluent are put forward.
【作者單位】: 中國科學(xué)院殼幔物質(zhì)與環(huán)境重點實驗室中國科學(xué)技術(shù)大學(xué)地球和空間科學(xué)技術(shù)學(xué)院;
【基金】:國家自然科學(xué)基金(41473066,41273076)
【分類號】:P597
[Abstract]:With the development of high precision isotope measurement technology, double diluent method has been proved to be necessary for many isotopic systems. Although the principle and calculation process of the double diluent method have been introduced in many literatures, the measurement and correction methods of the double diluent itself have not been systematically discussed. Starting with the introduction of isotopic mass fractionation law, the measuring principle of double diluent and the calculation formula and method of double diluent are presented in this paper. At the same time, the correction method of double diluent and its influence on isotopic measurement results are discussed. The complete formula of double diluent method and the derivation process of error transfer of double diluent are put forward.
【作者單位】: 中國科學(xué)院殼幔物質(zhì)與環(huán)境重點實驗室中國科學(xué)技術(shù)大學(xué)地球和空間科學(xué)技術(shù)學(xué)院;
【基金】:國家自然科學(xué)基金(41473066,41273076)
【分類號】:P597
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 ;校正方法座談會學(xué)術(shù)報告題錄(1985.7,成都)[J];石油地球物理勘探;1986年01期
2 詹道松;熒光分光光度計的熒光光譜校正方法驗證[J];海南大學(xué)學(xué)報(自然科學(xué)版);1994年03期
3 王際達(dá),張雄文;用預(yù)測-校正方法解非線性含擴散的色譜方程[J];鞍山鋼鐵學(xué)院學(xué)報;1996年01期
4 陳云浩,陶康華;綠化遙感中遮蔽校正方法研究[J];國土資源遙感;2000年02期
5 唐聲U,
本文編號:2128923
本文鏈接:http://www.sikaile.net/kejilunwen/diqiudizhi/2128923.html
最近更新
教材專著