節(jié)能填充墻在框架結(jié)構(gòu)中的應(yīng)用研究
本文關(guān)鍵詞: 框架結(jié)構(gòu) 節(jié)能 填充墻 保溫隔熱 出處:《西安科技大學(xué)》2015年碩士論文 論文類型:學(xué)位論文
【摘要】:框架結(jié)構(gòu)建筑中的填充墻作為外圍護(hù)結(jié)構(gòu)的重要組成部分,其保溫隔熱性能的優(yōu)劣會(huì)直接影響到建筑的總能耗。如何使墻體的節(jié)能構(gòu)造更好地適應(yīng)不同氣候條件是本文研究的重點(diǎn)。由于自保溫墻體在不同地區(qū)的節(jié)能適宜性研究目前還開展的較少。因此,針對(duì)自保溫節(jié)能填充墻在不同氣候區(qū)的應(yīng)用研究有著重要的意義。本文首先闡述了我國的建筑氣候區(qū)劃和氣候特點(diǎn),以及不同地區(qū)的氣候條件對(duì)建筑能耗的影響。其次,從人體熱平衡角度出發(fā),分析了熱平衡因子對(duì)人體熱舒適性造成的影響,以及室內(nèi)外環(huán)境因素對(duì)室內(nèi)熱環(huán)境形成的作用。通過對(duì)比三種不同構(gòu)造形式的外墻保溫系統(tǒng),指出自保溫墻體所擁有的突出優(yōu)勢(shì)。歸納了不同氣候區(qū)的外墻應(yīng)達(dá)到的節(jié)能設(shè)計(jì)要求。并依據(jù)各氣候區(qū)的外墻傳熱系數(shù)限值,計(jì)算出不同節(jié)能墻體材料所需的最小厚度,還結(jié)合所選材料的規(guī)格尺寸,提出了不同的自保溫節(jié)能填充墻構(gòu)造方案,并驗(yàn)算其熱惰性指標(biāo)。確定了滿足節(jié)能設(shè)計(jì)要求的填充墻構(gòu)造措施。為了進(jìn)一步驗(yàn)證其節(jié)能效果,本文利用清華大學(xué)開發(fā)的De ST能耗分析軟件,重點(diǎn)研究對(duì)比分析了在選用不同自保溫節(jié)能墻體構(gòu)造時(shí)建筑的自然室溫、全年采暖與制冷負(fù)荷以及傳熱系數(shù)、熱惰性指標(biāo)等參數(shù)變化對(duì)建筑負(fù)荷的影響及節(jié)能效果。結(jié)果表明:在嚴(yán)寒和寒冷地區(qū),采用蒸壓加氣混凝土砌塊與保溫材料復(fù)合而成的不同厚度的自保溫砌塊,對(duì)于框架結(jié)構(gòu)填充墻既可以滿足相應(yīng)的節(jié)能標(biāo)準(zhǔn),建筑全年熱負(fù)荷也會(huì)隨著保溫層厚度的加大而逐漸減少。而在夏熱冬冷和夏熱冬暖地區(qū),可直接采用蒸壓加氣混凝土砌塊、節(jié)能頁巖空心砌塊或者陶;炷量招钠鰤K,就能滿足相應(yīng)的節(jié)能要求,而建筑全年負(fù)荷的大小控制則需同時(shí)兼顧墻體的傳熱系數(shù)和熱惰性指標(biāo)的要求。研究得出:在夏熱冬冷地區(qū)運(yùn)用自保溫墻體節(jié)能技術(shù)最為適宜,可供選擇的保溫材料種類較多。綜上所述,節(jié)能的自保溫填充墻是一種很好的節(jié)能圍護(hù)結(jié)構(gòu),可以廣泛應(yīng)用在各類框架結(jié)構(gòu)建筑中,它的研究必將為今后的節(jié)能建筑提供更加廣闊的應(yīng)用前景。
[Abstract]:The infilled wall in the frame structure is an important part of the outer enclosure. Its thermal insulation performance will directly affect the total energy consumption of the building. How to make the wall energy saving structure adapt to different climatic conditions better is the focus of this paper. Sex studies are still being carried out less. It is of great significance to study the application of self-heat preservation and energy saving infill wall in different climate regions. Firstly, this paper expounds the climate regionalization and climate characteristics of buildings in China, and the influence of climate conditions in different regions on building energy consumption. From the point of view of thermal balance of human body, this paper analyzes the influence of heat balance factor on thermal comfort of human body, and the effect of indoor and outdoor environmental factors on the formation of indoor thermal environment. This paper points out the outstanding advantages of the self-insulating wall, sums up the energy saving design requirements of the exterior wall in different climate regions, and calculates the minimum thickness of the different energy saving wall materials according to the limit value of the outer wall heat transfer coefficient in each climate area. In addition, according to the size of the selected material, different construction schemes of self-insulation and energy-saving infill wall are put forward, and its thermal inertia index is checked. The construction measures of filling wall that meet the requirements of energy-saving design are determined. In order to further verify its energy-saving effect, Based on the energy consumption analysis software de St developed by Tsinghua University, this paper focuses on the comparative analysis of the natural room temperature, annual heating and refrigeration load and heat transfer coefficient of buildings with different self-insulation and energy-saving wall structures. The influence of parameters such as thermal inert index on building load and its energy-saving effect. The results show that in cold and cold regions, autoclaved aerated concrete blocks with different thickness are used to form self-insulating masonry blocks with different thickness, which are composed of autoclaved aerated concrete blocks and thermal insulation materials. For the infilled wall of frame structure, the energy saving standard can be satisfied, and the annual heat load of the building will gradually decrease with the increase of the thickness of the insulation layer, while in the hot summer and cold summer and warm summer areas, the autoclaved aerated concrete block can be used directly. Energy saving shale hollow blocks or ceramsite concrete hollow blocks can meet the corresponding energy-saving requirements. The heat transfer coefficient and thermal inertia index of the wall should be taken into account in the control of the annual load of the building. It is concluded that the energy saving technology of the self-insulating wall is the most suitable in the hot summer and cold winter area. To sum up, the energy saving self-insulation infill wall is a kind of good energy saving envelope structure, and can be widely used in all kinds of frame structure buildings. Its research will provide a wider application prospect for energy-saving buildings in the future.
【學(xué)位授予單位】:西安科技大學(xué)
【學(xué)位級(jí)別】:碩士
【學(xué)位授予年份】:2015
【分類號(hào)】:TU398
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 高效賢;;應(yīng)重視填充墻拉接[J];建筑工人;1992年06期
2 吳光遠(yuǎn);填充墻要后砌[J];浙江建筑;2000年04期
3 劉麗英;;填充墻裂縫的原因分析及防治[J];黑龍江科技信息;2007年03期
4 賈紅文;;淺析填充墻裂縫的原因及防治措施[J];山西建筑;2007年34期
5 秦現(xiàn)軍;;鋼筋混凝土框架結(jié)構(gòu)填充墻裂縫的成因與治理[J];山西建筑;2008年05期
6 劉海濤;劉迪;;淺議填充墻質(zhì)量通病的防治措施[J];科技創(chuàng)新導(dǎo)報(bào);2008年05期
7 劉欣;宋秀濤;;混凝土小型空心砌塊填充墻裂縫成因及控制[J];遼寧建材;2008年02期
8 李軍;瞿萬波;明章毅;;填充墻裂縫形成機(jī)制與控制措施[J];山西建筑;2008年15期
9 吉冬;岳小威;;控制砌體填充墻裂縫采取的措施[J];磚瓦;2008年06期
10 陳云才;;如何提高填充墻砌體的施工質(zhì)量[J];民營科技;2008年07期
相關(guān)會(huì)議論文 前10條
1 朱春林;;對(duì)于填充墻裂縫的分析及防治[A];齊齊哈爾市首屆學(xué)術(shù)年會(huì)論文匯編[C];2004年
2 胡天真;;框架結(jié)構(gòu)填充墻出現(xiàn)裂縫的分析[A];2012年鐵路技師論文集(安全專輯)[C];2013年
3 余春冠;董寧祺;劉永峰;;新型墻材填充墻的界面縫防治[A];砌體結(jié)構(gòu)與墻體材料——基本理論和工程應(yīng)用——2005年全國砌體結(jié)構(gòu)基本理論與工程應(yīng)用學(xué)術(shù)會(huì)議論文集[C];2005年
4 王曉耀;張?jiān)戚x;;框架梁與填充墻之間的滲水、裂縫的防治[A];土木建筑學(xué)術(shù)文庫(第13卷)[C];2010年
5 劉新立;涂文靜;;淺議填充墻和樓板裂縫的原因及防治[A];河南省土木建筑學(xué)會(huì)2009年學(xué)術(shù)大會(huì)論文集[C];2009年
6 盧華;李剛;李紅;李紹祥;;考慮填充墻影響的底層薄弱結(jié)構(gòu)抗震分析[A];第十三屆全國結(jié)構(gòu)工程學(xué)術(shù)會(huì)議論文集(第Ⅲ冊(cè))[C];2004年
7 吳劉占;孟軍;;淺談填充墻裂縫形成的原因及防治[A];土木建筑學(xué)術(shù)文庫(第11卷)[C];2009年
8 蔣利學(xué);;磚填充墻加固前后鋼筋混凝土框架的剛度與承載力[A];第17屆全國結(jié)構(gòu)工程學(xué)術(shù)會(huì)議論文集(第Ⅱ冊(cè))[C];2008年
9 歐陽仕成;;淺析混凝土空心砌塊填充墻產(chǎn)生裂縫的要素[A];土木建筑學(xué)術(shù)文庫(第14卷)[C];2010年
10 孫國利;王曙光;王滋軍;杜東升;;考慮填充墻作用的框架結(jié)構(gòu)非線性地震反應(yīng)分析[A];建筑結(jié)構(gòu)高峰論壇——復(fù)雜建筑結(jié)構(gòu)彈塑性分析技術(shù)研討會(huì)論文集[C];2012年
相關(guān)重要報(bào)紙文章 前4條
1 本報(bào)記者 王日譚;勵(lì)志建筑工人:研發(fā)填充墻技術(shù)尋發(fā)展[N];中華建筑報(bào);2009年
2 劉鐵男邋記者 趙蘊(yùn)穎;1700多平填充墻推倒重砌[N];大連日?qǐng)?bào);2007年
3 陳文雅;震裂商品房鑒定爭議[N];經(jīng)濟(jì)觀察報(bào);2008年
4 造造 編寫;魯班軟件實(shí)戰(zhàn)練兵場(36)[N];建筑時(shí)報(bào);2007年
相關(guān)博士學(xué)位論文 前1條
1 單思鏑;RC填充墻框架連續(xù)倒塌機(jī)制研究[D];哈爾濱工業(yè)大學(xué);2016年
相關(guān)碩士學(xué)位論文 前10條
1 常曉蕾;搖擺填充墻結(jié)構(gòu)體系減震性能及設(shè)計(jì)方法研究[D];西南科技大學(xué);2015年
2 蔣躍;填充墻對(duì)框架結(jié)構(gòu)抗震性能影響的數(shù)值模擬研究[D];遼寧工業(yè)大學(xué);2016年
3 李小龍;防屈曲支撐在填充墻框架結(jié)構(gòu)中的地震反應(yīng)分析[D];西安建筑科技大學(xué);2015年
4 胡宏駿;洞口對(duì)填充墻RC框架抗震性能影響研究[D];西南交通大學(xué);2016年
5 彭果;填充墻對(duì)多層RC框架結(jié)構(gòu)自振周期的影響分析[D];西南交通大學(xué);2016年
6 劉要峰;節(jié)能填充墻在框架結(jié)構(gòu)中的應(yīng)用研究[D];西安科技大學(xué);2015年
7 黃其神;鋼交錯(cuò)桁架結(jié)構(gòu)考慮填充墻分布不均的彈塑性分析[D];云南大學(xué);2016年
8 王廣慶;砌塊填充墻的精細(xì)化模擬與等效斜撐建模[D];哈爾濱工業(yè)大學(xué);2016年
9 孫昆;有開洞填充墻對(duì)框架結(jié)構(gòu)抗震性能影響的研究[D];西南交通大學(xué);2014年
10 張男;考慮填充墻的底部框架—抗震墻砌體房屋抗震性能研究[D];東北林業(yè)大學(xué);2014年
,本文編號(hào):1549045
本文鏈接:http://www.sikaile.net/jingjilunwen/jianzhujingjilunwen/1549045.html