天堂国产午夜亚洲专区-少妇人妻综合久久蜜臀-国产成人户外露出视频在线-国产91传媒一区二区三区

當(dāng)前位置:主頁 > 科技論文 > 建筑工程論文 >

裝配整體式螺栓鋼板箍連接框架柱抗火性能研究

發(fā)布時(shí)間:2018-04-25 21:24

  本文選題:裝配整體式 + 溫度場(chǎng); 參考:《西安建筑科技大學(xué)》2017年碩士論文


【摘要】:隨著裝配整體式結(jié)構(gòu)的日漸增多,對(duì)裝配式體系建筑的耐火性能的研究也日趨重要。本課題是在“新型抗震裝配整體式混合框架結(jié)構(gòu)體系實(shí)驗(yàn)研究與應(yīng)用”科技項(xiàng)目[1]的基礎(chǔ)上,對(duì)其中柱與柱連接實(shí)驗(yàn)的部分進(jìn)行的擴(kuò)展研究。這種新型的連接形式通過實(shí)驗(yàn)驗(yàn)證能夠很大程度上提高柱子的承載力和抗震性能,已經(jīng)應(yīng)用于實(shí)際工程中。目前對(duì)于這種新型的裝配整體式柱在火災(zāi)下和火災(zāi)后的力學(xué)性能的研究極少,因此對(duì)于這種新型柱的抗火性能的研究十分必要。本文主要從耐火極限和火災(zāi)后剩余承載力兩個(gè)方面對(duì)裝配整體式柱的抗火性能進(jìn)行研究,主要內(nèi)容:(1)采用ABAQUS有限元分析軟件,并選取合適的材料熱工參數(shù)及熱力學(xué)模型,建立了裝配整體式螺栓鋼板箍連接框架柱抗火分析的有限元模型。(2)模擬裝配整體式螺栓鋼板箍連接框架柱在ISO-834標(biāo)準(zhǔn)升(降)溫曲線作用下的溫度場(chǎng),并運(yùn)用相關(guān)的試驗(yàn)數(shù)據(jù),驗(yàn)證了溫度場(chǎng)及在熱力耦合的作用下有限元分析模型的正確性。(3)分析了軸壓比、偏心率、防火保護(hù)層、受火方式、鋼板箍厚度、配筋率和栓桿直徑等因素對(duì)裝配整體式螺栓鋼板箍連接框架柱耐火極限的影響,揭示了各參數(shù)對(duì)構(gòu)件軸向變形及耐火極限的影響規(guī)律。建立了相同工況現(xiàn)澆柱的有限元分析模型,將其耐火性能與裝配式柱耐火性能進(jìn)行對(duì)比。(4)模擬分析裝配整體式螺栓鋼板箍連接框架柱在受火后的剩余受壓承載力和受剪承載力的情況,并找出受火時(shí)間、受火方式、軸壓比、偏心率、防火保護(hù)層、配筋率和鋼板箍厚度等因素對(duì)構(gòu)件受火后剩余承載力的影響規(guī)律,并計(jì)算出在各種工況下火災(zāi)作用對(duì)裝配整體柱承載力影響系數(shù)。(5)根據(jù)論文的模擬結(jié)果和分析結(jié)論,對(duì)裝配整體式螺栓鋼板箍連接框架柱耐火性能的提高提出合理化建議,并通過對(duì)已加固的火災(zāi)后構(gòu)件承載力的計(jì)算,給出火災(zāi)后裝配整體式柱加固與修復(fù)的建議。
[Abstract]:With the increasing of assembly integral structure, it is more and more important to study the fire resistance of assembly system building. On the basis of "Experimental Research and Application of a New Type of Seismic Assembly Integrated Hybrid frame structure system", this paper studies the expansion of the experimental part of the column to column connection experiment in this project [1]. The experimental results show that this new type of connection can greatly improve the bearing capacity and seismic performance of the columns, and has been applied in practical engineering. At present, there is little research on the mechanical properties of this new type of assembled monolithic column under fire and after fire, so it is necessary to study the fire resistance of this new type of column. In this paper, the fire resistance of assembled monolithic columns is studied from two aspects of fire resistance limit and residual bearing capacity after fire. The main content is that ABAQUS finite element analysis software is used, and suitable thermal parameters and thermodynamic models of materials are selected. In this paper, a finite element model for fire resistance analysis of steel plate hoop connection frame columns with assembled integral bolts is established. (2) the temperature field of assembly bolted steel plate hoop connection frame columns under the action of ISO-834 standard rising (falling) curve is simulated, and the relevant test data are used. The correctness of the temperature field and the finite element analysis model under the action of thermal coupling is verified. (3) the axial compression ratio, eccentricity, fire protection layer, fire mode, thickness of steel plate hoop are analyzed. The influence of the ratio of reinforcement and the diameter of bolt on the fire resistance limit of the steel plate hoop frame column with assembled integral bolt is discussed. The influence of the parameters on the axial deformation and the fire resistance limit of the components is revealed. The finite element analysis model of cast-in-place column under the same working condition is established. Comparing its fire resistance with that of assembled columns, the paper simulates and analyzes the residual compressive and shear bearing capacity of the frame columns connected with steel plate and hoop of assembled integral bolts after fire, and finds out the fire time and fire mode. The influence of axial compression ratio, eccentricity ratio, fire protection layer, reinforcement ratio and thickness of steel plate hoop on the residual bearing capacity of members after fire, The influence coefficient of fire action on the bearing capacity of assembled monolithic columns under various working conditions is calculated. According to the simulation results and analytical conclusions of the paper, reasonable suggestions are put forward for the improvement of fire resistance of steel plate hoop frame columns with assembled integral bolts. Through the calculation of the bearing capacity of the reinforced members after fire, the suggestion of strengthening and repairing the assembled integral columns after fire is given.
【學(xué)位授予單位】:西安建筑科技大學(xué)
【學(xué)位級(jí)別】:碩士
【學(xué)位授予年份】:2017
【分類號(hào)】:TU352.5

【參考文獻(xiàn)】

相關(guān)期刊論文 前10條

1 周立人;毛小勇;張翔;;角鋼加固鋼筋混凝土柱耐火極限試驗(yàn)研究[J];土木工程學(xué)報(bào);2017年03期

2 張玉琢;呂學(xué)濤;王微微;;鋼管鋼筋混凝土短柱火災(zāi)后剩余承載力試驗(yàn)與有限元分析[J];防災(zāi)減災(zāi)工程學(xué)報(bào);2015年06期

3 劉洪濤;李亮;;溫度場(chǎng)和應(yīng)力場(chǎng)聯(lián)合作用下鋼筋混凝土柱力學(xué)性能研究[J];建筑結(jié)構(gòu);2015年20期

4 趙建魁;方秦;陳力;李大鵬;;爆炸與火荷載聯(lián)合作用下RC梁耐火極限的數(shù)值分析[J];天津大學(xué)學(xué)報(bào)(自然科學(xué)與工程技術(shù)版);2015年10期

5 呂學(xué)濤;張玉琢;王禹;王微微;;相對(duì)兩面受火的方鋼管鋼筋混凝土柱耐火極限[J];火災(zāi)科學(xué);2014年01期

6 徐玉野;楊清文;吳波;徐明;;高溫后鋼筋混凝土短柱抗震性能試驗(yàn)研究[J];建筑結(jié)構(gòu)學(xué)報(bào);2013年08期

7 苗吉軍;公偉;陳娜;劉延春;邊忠亮;;使用損傷鋼筋混凝土柱高溫作用下受力性能試驗(yàn)研究與有限元分析[J];建筑結(jié)構(gòu)學(xué)報(bào);2013年08期

8 李俊華;唐躍鋒;劉明哲;于長(zhǎng)海;蕭寒;;外包鋼加固火災(zāi)后鋼筋混凝土柱的試驗(yàn)研究[J];工程力學(xué);2012年05期

9 唐躍鋒;劉明哲;于長(zhǎng)海;李俊華;;火災(zāi)后鋼筋混凝土柱剩余承載力研究[J];寧波大學(xué)學(xué)報(bào)(理工版);2011年04期

10 楊清文;;火災(zāi)下混凝土柱的溫度場(chǎng)影響分析[J];福建建筑;2011年06期

相關(guān)會(huì)議論文 前1條

1 張家廣;霍靜思;肖巖;;火災(zāi)全過程后鋼筋混凝土柱滯回性能試驗(yàn)研究[A];第18屆全國(guó)結(jié)構(gòu)工程學(xué)術(shù)會(huì)議論文集第Ⅲ冊(cè)[C];2009年

相關(guān)博士學(xué)位論文 前5條

1 劉發(fā)起;火災(zāi)下與火災(zāi)后圓鋼管約束鋼筋混凝土柱力學(xué)性能研究[D];哈爾濱工業(yè)大學(xué);2014年

2 鄭先超;新型裝配式混合結(jié)構(gòu)抗震體系試驗(yàn)及理論分析[D];西安建筑科技大學(xué);2013年

3 宋天詣;火災(zāi)后鋼—混凝土組合框架梁—柱節(jié)點(diǎn)的力學(xué)性能研究[D];清華大學(xué);2010年

4 林曉康;火災(zāi)后鋼管混凝土壓彎構(gòu)件的滯回性能研究[D];福州大學(xué);2006年

5 劉威;鋼管混凝土局部受壓時(shí)的工作機(jī)理研究[D];福州大學(xué);2005年

相關(guān)碩士學(xué)位論文 前4條

1 張翔;外包鋼加固鋼筋混凝土柱的抗火分析及耐火保護(hù)方法[D];蘇州科技學(xué)院;2014年

2 劉展;新型裝配整體式螺栓鋼板箍框架柱優(yōu)化設(shè)計(jì)研究[D];西安建筑科技大學(xué);2013年

3 劉發(fā)起;三面受火的矩形鋼管混凝土柱抗火性能研究[D];哈爾濱工業(yè)大學(xué);2010年

4 江瑩;火災(zāi)后方鋼管混凝土柱—鋼梁連接節(jié)點(diǎn)的力學(xué)性能分析[D];清華大學(xué);2008年