能源樁儲(chǔ)熱分析與數(shù)值模擬研究
本文關(guān)鍵詞: 能源樁 儲(chǔ)熱 溫度場(chǎng) 數(shù)值模擬 出處:《湖北工業(yè)大學(xué)》2017年碩士論文 論文類型:學(xué)位論文
【摘要】:近幾年,我國(guó)經(jīng)濟(jì)不斷發(fā)展,人們對(duì)居住的品質(zhì)也越來(lái)越高,建筑的空調(diào)系統(tǒng)(供熱和供冷)是人們生活所必須的,然而這部分能耗占到社會(huì)總能耗的25%~30%。在我國(guó),大部分地區(qū)主要以煤炭能源作為供熱資源,煤炭能源在燃燒的過(guò)程中會(huì)產(chǎn)生大量的有毒有害的氣體,給環(huán)境帶來(lái)一系列的問(wèn)題。在各種新能源和可再生能源中,地源熱泵系統(tǒng)是一種可持續(xù)的,環(huán)境友好的能源系統(tǒng),利用地?zé)崮茉垂┡?制冷的建筑,符合綠色建筑設(shè)計(jì)要求[1]。地球的地表下中包含存儲(chǔ)的地?zé)崮茉吹木薮鬂摿?地源熱泵技術(shù)就是充分利用這種能量用于加熱與冷卻的一種建筑節(jié)能技術(shù)[2]。從90年代至今,地源熱泵技術(shù)開(kāi)始從全世界各地得到了大力發(fā)展與廣泛應(yīng)用。雖然地源熱泵具備經(jīng)濟(jì)、節(jié)能、綠色環(huán)保等眾多優(yōu)點(diǎn),但并非完美,其不足主要表現(xiàn)在三個(gè)方面:1.項(xiàng)目開(kāi)始投入資金偏高,2.不合理的布置方式占用了地下空間,3.錯(cuò)誤的排放方式污染地下水。本文對(duì)能源樁技術(shù)的儲(chǔ)熱進(jìn)行了較為系統(tǒng)的分析,本文主要工作與研究成果如下:(1)總結(jié)了國(guó)內(nèi)與國(guó)外關(guān)于能源樁技術(shù)的研究現(xiàn)狀,同時(shí)介紹了能源樁目前存在的主要問(wèn)題及研究?jī)r(jià)值;(2)分析了能源樁與周圍土體之間發(fā)生熱交換的熱力學(xué)理論;同時(shí)分析了樁埋管換熱器與混凝土及土壤之間的熱傳遞過(guò)程,建立了熱交換模型;(3)采用MIDAS/CIVIL有限元計(jì)算軟件建立了有限元模型,分析了不同工況下對(duì)能源樁換熱能力的影響,發(fā)現(xiàn)得入口水溫與土壤環(huán)境溫度相差越大,進(jìn)出口溫差越大,但最終熱擴(kuò)散半徑相差不大;樁直徑越大,樁的儲(chǔ)熱能力越強(qiáng);同時(shí)樁直徑為800mm時(shí),管間距設(shè)置為400mm,樁儲(chǔ)熱最合理。(4)分析了“U”型與“W”型換熱器換熱性能對(duì)比試驗(yàn),通過(guò)數(shù)值分析得出在相同工況下兩種換熱器的進(jìn)出口水溫、換熱功率、土壤溫度變化及熱擴(kuò)散半徑隨時(shí)間變化曲線,發(fā)現(xiàn)W型的換熱性能優(yōu)于U型,但經(jīng)濟(jì)性不如U型換熱管。(5)分析了群樁模擬,在群樁儲(chǔ)熱效應(yīng)下,每根能量樁的熱影響半徑能達(dá)到2m,這明顯要比單樁的熱影響半徑大,說(shuō)明群樁的熱效應(yīng)并非單樁的熱疊加。
[Abstract]:In recent years, the economy of our country has been developing continuously, and the quality of people's living is getting higher and higher. The air conditioning system (heating and cooling) in buildings is necessary for people's daily life. However, this part of energy consumption accounts for 25% of the total energy consumption of society. In our country, Most areas mainly use coal energy as heating resources, coal energy will produce a large number of toxic and harmful gases in the process of combustion, which will bring a series of problems to the environment. The ground-source heat pump system is a sustainable, environment-friendly energy system that uses geothermal energy for heating / cooling buildings that meet the design requirements of green buildings [1]. Ground-source heat pump (GSHP) technology is a kind of building energy saving technology that makes full use of this energy for heating and cooling. Ground-source heat pump technology has been developed and widely used from all over the world. Although ground-source heat pump has many advantages, such as economy, energy saving, green and environmental protection, it is not perfect. The deficiency is mainly manifested in three aspects: 1.The project begins to invest too much money. 2. Unreasonable arrangement occupies underground space 3.The wrong discharge way pollutes groundwater. This paper makes a systematic analysis on heat storage of energy pile technology. The main work and research results of this paper are as follows: (1) summarizing the research status of energy pile technology both at home and abroad. At the same time, the main problems and research value of energy pile are introduced. The thermodynamic theory of heat exchange between energy pile and surrounding soil is analyzed, and the heat transfer process between pile buried tube heat exchanger and concrete and soil is also analyzed. The heat exchange model is established. The finite element model is established by using MIDAS/CIVIL finite element calculation software. The influence of different working conditions on the heat transfer capacity of energy pile is analyzed. It is found that the greater the difference between inlet water temperature and soil environmental temperature is, the greater the difference between inlet and outlet temperature is. But the final thermal diffusion radius is not different; the bigger the pile diameter, the stronger the heat storage capacity of pile; at the same time, when the diameter of pile is 800mm, the distance between pipe and pipe is set to 400mm, and the heat storage of pile is most reasonable. The comparative test of heat transfer performance of "U" type heat exchanger and "W" type heat exchanger is analyzed. Through numerical analysis, the curves of inlet and outlet water temperature, heat transfer power, soil temperature change and thermal diffusion radius with time are obtained under the same operating conditions. It is found that the heat transfer performance of W type is better than that of U type. But the economic efficiency is not as good as that of U-type heat exchanger pipe. (5) the simulation of pile group is analyzed. Under the heat storage effect of pile group, the thermal influence radius of each energy pile can reach 2 m, which is obviously larger than that of single pile, which indicates that the thermal effect of pile group is not the thermal superposition of single pile.
【學(xué)位授予單位】:湖北工業(yè)大學(xué)
【學(xué)位級(jí)別】:碩士
【學(xué)位授予年份】:2017
【分類號(hào)】:TU83
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 李守圣;趙大軍;趙研;黃晟輝;;混凝土儲(chǔ)熱樁的儲(chǔ)熱試驗(yàn)研究[J];人民黃河;2010年02期
2 李永亮;金翼;黃云;葉鋒;汪翔;李大成;王彩霞;丁玉龍;;儲(chǔ)熱技術(shù)基礎(chǔ)(Ⅰ)——儲(chǔ)熱的基本原理及研究新動(dòng)向[J];儲(chǔ)能科學(xué)與技術(shù);2013年01期
3 李守圣;趙大軍;趙研;黃晟輝;;一種新的熱能地下存儲(chǔ)技術(shù)[J];應(yīng)用能源技術(shù);2009年11期
4 王華軍;齊承英;;土壤高溫儲(chǔ)熱熱濕遷移過(guò)程的初步研究[J];太陽(yáng)能學(xué)報(bào);2009年12期
5 齊承英;王華軍;;土壤高溫儲(chǔ)熱技術(shù)研究現(xiàn)狀與進(jìn)展[J];河北工業(yè)大學(xué)學(xué)報(bào);2013年01期
6 程曉敏;張?jiān)?;基于Al-Si-Cu-Mg-Zn合金的套管式儲(chǔ)熱系統(tǒng)設(shè)計(jì)[J];中國(guó)水運(yùn)(下半月);2009年12期
7 黃晟輝;趙大軍;馬銀龍;;太陽(yáng)能跨季節(jié)地下儲(chǔ)熱技術(shù)[J];煤氣與熱力;2010年12期
8 張建國(guó),陳永昌,林宏佐;太陽(yáng)能沸石儲(chǔ)熱技術(shù)的實(shí)驗(yàn)研究[J];北京工業(yè)大學(xué)學(xué)報(bào);2005年01期
9 ;可用于建筑節(jié)能的相變儲(chǔ)熱材料[J];大眾用電;2007年09期
10 李永亮;金翼;黃云;葉鋒;汪翔;李大成;王彩霞;丁玉龍;;儲(chǔ)熱技術(shù)基礎(chǔ)(Ⅱ)——儲(chǔ)熱技術(shù)在電力系統(tǒng)中的應(yīng)用[J];儲(chǔ)能科學(xué)與技術(shù);2013年02期
相關(guān)會(huì)議論文 前4條
1 王宏麗;鄒志榮;陳紅武;張勇;;溫室中應(yīng)用相變儲(chǔ)熱技術(shù)研究進(jìn)展[A];《中國(guó)設(shè)施農(nóng)業(yè)可持續(xù)發(fā)展》論壇論文資料匯編[C];2010年
2 金翼;冷光輝;葉鋒;葛志偉;黃云;丁玉龍;;中高溫相變儲(chǔ)熱技術(shù)在工業(yè)余熱回收中的應(yīng)用[A];第一屆全國(guó)儲(chǔ)能科學(xué)與技術(shù)大會(huì)摘要集[C];2014年
3 張正國(guó);;復(fù)合相變儲(chǔ)熱材料的研究及應(yīng)用[A];第一屆全國(guó)儲(chǔ)能科學(xué)與技術(shù)大會(huì)摘要集[C];2014年
4 甘雪菲;何正斌;伊松林;張璧光;;石蠟相變儲(chǔ)熱系統(tǒng)放熱效率的研究[A];全國(guó)農(nóng)村清潔能源與低碳技術(shù)學(xué)術(shù)研討會(huì)論文集[C];2011年
相關(guān)重要報(bào)紙文章 前1條
1 遼寧 張國(guó)清;自制儲(chǔ)熱電暖器[N];電子報(bào);2004年
相關(guān)博士學(xué)位論文 前4條
1 王培倫;相變儲(chǔ)熱換熱器設(shè)計(jì)及強(qiáng)化換熱機(jī)理研究[D];中國(guó)地質(zhì)大學(xué)(北京);2015年
2 王軍偉;碟式斯特林熱發(fā)電熔融鹽儲(chǔ)熱裝置及儲(chǔ)熱腔腐蝕行為研究[D];蘭州理工大學(xué);2013年
3 李傳常;礦物基復(fù)合儲(chǔ)熱材料的制備與性能調(diào)控[D];中南大學(xué);2013年
4 趙嵩穎;能量樁儲(chǔ)熱試驗(yàn)與數(shù)值模擬研究[D];吉林大學(xué);2015年
相關(guān)碩士學(xué)位論文 前10條
1 邢麗婧;鋁基合金相變儲(chǔ)熱材料熱物性及儲(chǔ)熱特性研究[D];華北電力大學(xué);2015年
2 周權(quán);AA-CAES概念系統(tǒng)設(shè)計(jì)計(jì)算及性能分析[D];華北電力大學(xué);2015年
3 杜中玲;太陽(yáng)能中高溫?zé)崂眉捌鋬?chǔ)熱技術(shù)的應(yīng)用研究[D];東南大學(xué);2015年
4 馬小琨;基于水合鹽吸附的跨季節(jié)儲(chǔ)熱特性數(shù)值研究[D];華北電力大學(xué)(北京);2016年
5 孫世敏;氫氧化鈣鋅—石墨和氯化鈣—石墨化學(xué)儲(chǔ)熱材料[D];西北大學(xué);2016年
6 湯黎;能源樁儲(chǔ)熱分析與數(shù)值模擬研究[D];湖北工業(yè)大學(xué);2017年
7 張?jiān)?基于Al-Si-Cu-Mg-Zn合金的高溫儲(chǔ)熱系統(tǒng)設(shè)計(jì)[D];武漢理工大學(xué);2009年
8 葉建元;Mg-Cu-Zn-Al-Si合金儲(chǔ)熱性能及其腐蝕性研究[D];武漢理工大學(xué);2014年
9 何黎明;太陽(yáng)能熱發(fā)電中鋁基合金高溫相變儲(chǔ)熱材料及儲(chǔ)熱系統(tǒng)研究[D];武漢理工大學(xué);2008年
10 宮殿清;基于Al-Si-Cu-Mg-Zn合金的高溫相變儲(chǔ)熱材料制備與儲(chǔ)熱性能研究[D];武漢理工大學(xué);2008年