[Abstract]:The development of power market needs a stable and reliable operating environment. A safe, high quality and economical power system is an important condition for power and electricity trading. With the increasing peak and valley difference of power grid in various regions of China, the power quality and safe operation of power grid are greatly affected, and the dispatching operation is becoming more and more difficult. Automatic power generation control is a necessary condition to realize online economic dispatching, which can optimize power generation scheduling and reduce power generation cost. The two rules are an auxiliary management measure to maintain the safe and stable operation of the power system and ensure the power quality. This paper mainly focuses on the current mainstream 600MW units, and puts forward a safe and economic operation strategy based on load response rate. Firstly, the related research on automatic power generation control and economic evaluation of thermal power plants at home and abroad is summarized and summarized. Secondly, the relevant data are widely collected to interpret the theory of operation optimization strategy and economy of thermal power plant in detail. According to the operation optimization practice of a power plant unit based on load response rate in Hebei South Power Network, The influencing factors and work results of maximizing the operation benefit of this kind of unit in Hebei South Power Network are studied and analyzed. Thirdly, according to the relevant theoretical data and the actual situation of a power plant in southern Hebei network, the operation optimization and economic comprehensive evaluation of thermal power plant based on load response rate are put forward. This paper makes a comprehensive analysis and evaluation of the operation of the thermal power plant based on the "two detailed rules" in order to verify and explore the main influencing factors on the operation economy of this kind of thermal power plant in Hebei Southern Power Network. Finally, the influence degree of these factors is proved by the implementation of the two detailed rules of the power plant, and the safe and economical balance point of the unit is found from optimizing the load response rate of the unit, from the performance of the DCS system of the generator set and the reliability of the equipment. The strategy of how to improve the load response rate of generator set is put forward in many aspects, such as enterprise management, and the important practical significance of economic operation of thermal power plant based on equipment reliability management is explained. To realize the maximization and sustainable development of comprehensive benefit in the whole life period of thermal power plant.
【學(xué)位授予單位】:華北電力大學(xué)
【學(xué)位級(jí)別】:碩士
【學(xué)位授予年份】:2013
【分類號(hào)】:TM621;F426.61
【參考文獻(xiàn)】
相關(guān)期刊論文 前10條
1 葉成;許曉華;史永東;池虹;;火電廠主要設(shè)備節(jié)能降耗經(jīng)濟(jì)性分析[J];電力設(shè)備;2008年02期
2 盧連成;肖凌濤;溫柏堅(jiān);褚文捷;;媽灣電廠廠級(jí)自動(dòng)發(fā)電控制系統(tǒng)的設(shè)計(jì)與實(shí)現(xiàn)[J];電力系統(tǒng)自動(dòng)化;2011年17期
3 邢金峰;何占賓;楊興宇;習(xí)新魁;楊立波;;自動(dòng)發(fā)電控制在河北南部電網(wǎng)中的應(yīng)用[J];電力自動(dòng)化設(shè)備;2011年04期
4 張琦;楊斌;孫永再;;火電廠自動(dòng)發(fā)電控制系統(tǒng)的優(yōu)化設(shè)計(jì)[J];山西電力;2010年01期
5 蘇偉;;提高火電廠運(yùn)行經(jīng)濟(jì)性的探討[J];廣東科技;2009年22期
6 張玉勝;;火電廠AGC指標(biāo)提高與安全經(jīng)濟(jì)運(yùn)行探討[J];科技創(chuàng)新與應(yīng)用;2012年30期
7 李平康;火電廠AGC及其可視化仿真實(shí)現(xiàn)[J];華北電力技術(shù);2000年10期
8 李曉金 ,曹洪濤 ,張春發(fā);火電機(jī)組耗差分析系統(tǒng)的實(shí)現(xiàn)方式和數(shù)學(xué)模型的分析研究[J];華北電力技術(shù);2003年08期
9 周紅英;;AGC新模式下協(xié)調(diào)控制系統(tǒng)的分析及改進(jìn)[J];華北電力技術(shù);2010年04期
10 劉銘剛;自動(dòng)發(fā)電控制技術(shù)在電網(wǎng)中的應(yīng)用[J];華北電力大學(xué)學(xué)報(bào);2002年01期
本文編號(hào):2481565
本文鏈接:http://www.sikaile.net/guanlilunwen/shengchanguanlilunwen/2481565.html